Introduction: Surgical versus orthopedic treatments of acromioclavicular disjunction are still debated. The aim of this study was to measure horizontal and vertical acromion's displacement after cutting the ligament using standard X-ray and an opto-electronic system on cadaver.
Materials And Methods: Ten cadaveric shoulders were studied. A sequential ligament's section was operated by arthroscopy. The sequence of cutting was chosen to fit with Rockwood's grade. The displacement of the acromion was measured on standard X-ray and with an opto-electronic system allowing measuring of the horizontal displacement. Statistical comparisons were performed using a paired Student's t test with significance set at p < 0.05.
Results: Cutting the coracoclavicular ligament and delto-trapezius muscles cause a statistical downer displacement of the acromion, but not after sectioning the acromioclavicular ligament. The contact surface between the acromion and the clavicle decreases statistically after sectioning the acromioclavicular ligament and the coracoclavicular ligament with no effect of sectioning the delto-trapezius muscles. Those results are superposing with those dealing with the anterior translation.
Discussion: The measure concerning the acromioclavicular distance and the coracoclavicular distance are superposing with those of Rockwood. However, there is a significant horizontal translation after cutting the acromioclavicular ligament. Taking into account this displacement, it may be interesting to choose either surgical or orthopedic treatment.
Conclusion: There is a correlation between anatomical damage and importance of instability. Horizontal instability is misevaluated in clinical practice.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1007/s00276-012-0953-8 | DOI Listing |
Talanta
December 2024
Thin Films and Materials Science Research Laboratory, Department of Physics, Dayanand Science College, Latur, Maharashtra, 413512, India. Electronic address:
In this study, we report the synthesis, optical characterization and ultra-sensitive ammonia gas sensing properties of Mg-doped ZnO cauliflower like nanostructures obtained via chemical spray pyrolysis technique. The morphological and structural properties of the prepared films were investigated by Field Emission Scanning electron microscope (FESEM) and X-ray diffraction (XRD). Gas sensing and optical characterizations were carried out using Keithley electrometer and Uv-Vis.
View Article and Find Full Text PDFAdv Sci (Weinh)
November 2024
School of Physics and Opto-Electronic Technology, Collaborative Innovation Center of Rare-Earth Optical Functional Materials and Devices Development, Baoji University of Arts and Sciences, Baoji, Shaanxi, 721016, P. R. China.
Macromol Rapid Commun
December 2024
Advanced Polymer Laboratory, Department of Polymer Science and Technology, Government College of Engineering and Leather Technology (Post Graduate), Maulana Abul Kalam Azad University of Technology, Salt Lake, Kolkata, West Bengal, 700106, India.
Excited-state intramolecular proton transfer (ESIPT)-associated dual-state emissive aliphatic dual-light emitting conducting polymers (DLECPs) having oxidation-reduction capacities are prepared polymerizing 2-acrylamido-2-methylpropane-1-sulfonic acid, methacrylic acid, and 2-methyl-3-(N-(2-methyl-1-sulfopropan-2-yl)acrylamido)propanoic acid monomers. Of as-synthesized DLECPs, nuclear magnetic resonance (NMR) and Fourier transform infrared (FTIR) spectroscopies, fluorescent enhancements (I/I), and computational investigation indicate intriguing photophysical features in DLECP3 (optimum composition). In DLECP3, ─CONH─, ─CON<, and ─COOH subluminophores are recognized by density-functional theory (DFT)/time-dependent-DFT calculations and experimental investigations.
View Article and Find Full Text PDFAdv Mater
November 2024
Songshan Lake Materials Laboratory, Dongguan, Guangdong, 523808, China.
Anal Bioanal Chem
November 2024
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, 100190, China.
The preparation of histology slides is a critical step in histopathology, and poor-quality histology slides with weak adhesion of tissue sections to the substrate often affect diagnostic accuracy and sometimes lead to diagnostic failure due to tissue section detachment. This issue has been of concern and some methods have been proposed to enhance tissue-substrate adhesion. Unfortunately, quantitative analysis of the adhesion between tissue sections and glass slides is still challenging.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!