Background: Sarcosine is reported to be a differential metabolite that is greatly increased during prostate cancer (PCa) progression. In this study, we assessed the role of serum sarcosine as a biomarker for PCa, as well as any association between sarcosine levels and clinical-pathological parameters.

Methods: Sarcosine was measured by fluorometric assay in serum samples from 290 PCa patients and 312 patients with no evidence of malignancy (NEM), confirmed by 8-12 core prostate biopsies. Nonparametric statistical tests and receiver operating characteristics (ROC) analyses were performed to assess the diagnostic performance of sarcosine in different (prostate-specific antigen) PSA ranges.

Results: ROC analyses in subjects with PSA < 4 ng/ml showed a higher predictive value of sarcosine (AUC = 0.668) versus total PSA (AUC = 0.535) (P = 0.03), whereas for the other two PSA ranges (4-10 ng/ml and >10 ng/ml), percent ratio of free to total PSA (%fPSA) showed a predictive superiority over sarcosine. Moreover, in patients with a PSA < 4 ng/ml, the percentage of low/intermediate-grade cancers was positively associated with sarcosine levels (P = 0.005). The specificities for serum sarcosine, %fPSA, PSA, and the logistic regression model at 95% sensitivity were 24.4, 3.41, 2.22, and 28.4%, respectively.

Conclusions: We provide evidence that serum sarcosine has a higher predictive value than tPSA and %fPSA in patients with PSA < 4 ng/ml. Moreover, sarcosine levels were significantly different in low grade versus high grade cancers in this subset of patients, suggesting that this marker may be a further tool not only for diagnosing PCa in normal PSA and abnormal DRE/TRUS patients but also for selecting candidates for non-aggressive therapies and active surveillance.

Download full-text PDF

Source
http://dx.doi.org/10.1002/pros.22514DOI Listing

Publication Analysis

Top Keywords

serum sarcosine
8
prostate cancer
8
roc analyses
8
sarcosine
6
serum
4
sarcosine increases
4
increases accuracy
4
accuracy prostate
4
cancer detection
4
patients
4

Similar Publications

Portable Amperometric Biosensor Enhanced with Enzyme-Ternary Nanocomposites for Prostate Cancer Biomarker Detection.

Biosensors (Basel)

December 2024

Department of Cogno-Mechatronics Engineering, College of Nanoscience and Nanotechnology, Pusan National University, Busan 46241, Republic of Korea.

Enzyme-based portable amperometric biosensors are precise and low-cost medical devices used for rapid cancer biomarker screening. Sarcosine (Sar) is an ideal biomarker for prostate cancer (PCa). Because human serum and urine contain complex interfering substances that can directly oxidize at the electrode surface, rapid Sar screening biosensors are relatively challenging and have rarely been reported.

View Article and Find Full Text PDF

Background: Sarcopenia at the time of liver transplantation (LT) is an established risk factor for mortality following LT. However, most studies in this context have defined sarcopenia by one-time, static measurements. The aims of this study were (I) to determine the impact of the rate of muscle loss in waitlisted LT recipients on post-LT outcomes and (II) to identify patterns of serum metabolites associated with patients with more progressive sarcopenia.

View Article and Find Full Text PDF

A straightforward distance-based paper analytical device (dPAD) was developed for monitoring sarcosine levels in human samples for the rapid diagnosis and prognosis of prostate cancer and related symptoms. This assay eliminates the need for the expensive horseradish peroxidase (HRP) enzyme by utilizing carbon nanodots (CDs) as a peroxidase-like nanozyme. The proposed dPAD sensor consists of a sample zone pre-deposited with sarcosine oxidase (SOx) and CDs, and a detection zone containing 3,3',5,5'-tetramethylbenzidine (TMB).

View Article and Find Full Text PDF

Selective and sensitive sarcosine detection is crucial due to its recent endorsement as a prostate cancer (PCa) biomarker in clinical diagnosis. The reduced graphene oxide-cobalt nickel tungsten boron oxides (CoNiWBO/rGO) nanocomposite is developed as a non-enzymatic electrochemical sensor for sarcosine detection in PCa patients' serum. CoNiWBO/rGO is synthesized by the chemical reduction method via a one-pot reduction method followed by calcination at 500 °C under a nitrogen environment for 2 h and characterized by UV-Vis, XRD, TGA, and SEM.

View Article and Find Full Text PDF

The main hurdles with current therapies for major depressive disorder (MDD) include lack of efficacy, therapeutic latency, and adverse drug reactions. Add-on therapy to conventional antidepressants may result in better therapeutic outcomes to overcome these obstacles. Sarcosine (N-methyl glycine), an endogenous amino acid that acts by modulating the NMDA receptor, is available as a dietary supplement.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!