  • Atrioventricular nodal reentrant tachycardia (AVNRT) is frequently treated in children using cryoablation, showing high acute success rates of 97%, particularly with 6-mm-tip catheters.
  • Recurrence rates after cryoablation in pediatric patients were found to be 7.3%, with the 4-mm-tip catheter having a higher recurrence rate compared to the larger catheter.
  • Overall, cryoablation for treating AVNRT in children demonstrates effectiveness and safety, with results comparable to those achieved with radiofrequency ablation (RFA).

Article Abstract

Atrioventricular nodal reentrant tachycardia (AVNRT), a common tachycardia in children, is routinely treated by catheter ablation using radiofrequency or cryothermal energy. Acute success rates of 95-97 % are reported for cryoablation, similar to those achieved with radiofrequency ablation (RFA). However, early studies reported higher recurrence rates after cryoablation for treatment of AVNRT than those reported for RFA. This study evaluated the success and recurrence rates for cryoablation in a current cohort of pediatric patients across several institutions. Patients 21 years old or younger with AVNRT who underwent cryoablation at five participating centers between 2004 and 2009 were retrospectively reviewed. Patient demographics and procedural data were extracted from patient records and analyzed. A total of 434 patients with AVNRT who underwent cryoablation were identified. Cryoablation was used as the exclusive ablation method for 379 patients. For 97 % (368/379) of these patients, cryoablation was acutely successful. A higher acute success rate was found with the 6-mm-tip catheter (99 %) than with the 4-mm-tip catheter (91 %) (p < 0.01). Recurrence was experienced by 7.3 % of the patients. Recurrence was more likely for those treated with the 4-mm-tip catheter (6/42, 14 %) than for those who had the larger catheters (12/204, 6 %) No patient experienced permanent heart block. Success and recurrence rates for this cohort of patients were similar to those reported for RFA used to treat AVNRT in pediatric patients. The findings show a higher success rate and a lower recurrence rate after cryoablation with a 6-mm-tip catheter than after use of the 4-mm-tip catheter, with an associated excellent safety profile.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00246-012-0273-0DOI Listing

Publication Analysis

Top Keywords

recurrence rates
12
4-mm-tip catheter
12
cryoablation
9
atrioventricular nodal
8
nodal reentrant
8
reentrant tachycardia
8
tachycardia children
8
acute success
8
rates cryoablation
8
reported rfa
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!