Background: The DIEAP flap has gained popularity for breast reconstruction worldwide. Despite DIEAP flap arterial anatomy being well known, venous congestion is still an important complication and the literature on DIEAP flap venous anatomy is lacking. Venous drainage is less predictable and research on venous perforators is of increasing interest. The aim of this study was to investigate the anatomical distribution, diameters and relationships between arterial and venous perforators and their source vessels using Duplex ultrasonography, in order to evaluate the potential benefits of pre-operative evaluation of DIEAP flap venous perforators.

Methods: Prospectively, 140 patients undergoing DIEAP flap breast reconstruction, were pre-operatively assessed using Duplex ultrasonography for location and diameter of arterial and venous perforators, DIEA, DIEV, and SIEV. Perforators were plotted laterally and inferiorly from the umbilicus. Means were compared using t-tests. Pearson's correlation coefficients were calculated.

Results: We identified 702 arterial and 355 venous perforators in 280 lower hemi-abdomens. No venous perforators were identified in 9 (6.5%) patients; none on the right in 25 (17.9%) and none on the left in 36 (25.7%). Venous perforators were larger on the right (p=0.031) but DIEV and SIEV diameters were not statistically different on either sides. The diameters of DIEA, DIEV, perforating arteries and veins were correlated, but unrelated to the diameter of the SIEV. When a medium/large perforator vein is identified first, there is a 93.5% chance of finding an associated medium/large perforator artery; this reduces to 69.8% when a medium/large perforator artery is first identified.

Conclusions: There is no correlation between the sizes of perforator veins and DIEV, and the size of the SIEV. Our data suggests that first identifying a medium/large venous perforator increases the chances of finding a better suitable perforator complex. Pre-operative evaluation of venous perforators may be of great interest for its potential clinical benefits.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.bjps.2012.02.026DOI Listing

Publication Analysis

Top Keywords

venous perforators
32
dieap flap
20
venous
13
duplex ultrasonography
12
medium/large perforator
12
breast reconstruction
8
flap venous
8
perforators
8
arterial venous
8
pre-operative evaluation
8

Similar Publications

Acquired reactive perforating dermatosis (ARPD) is characterized by its onset after the age of 18 years, umbilicated papules or nodules with a central keratotic plug, and the presence of necrotic collagen tissue within an epithelial crater. ARPD is strongly associated with systemic diseases such as diabetes mellitus (DM) and chronic renal failure, which may contribute to ARPD through factors including microcirculatory disturbances and the deposition of metabolic byproducts, including advanced glycation end-products and calcium. Here, we report a case of ARPD that improved following DM treatment and catheter-based interventions for peripheral artery disease (PAD).

View Article and Find Full Text PDF

Characteristics of In Vivo Lesion Formation With a Temperature-Controlled Diamond-Tip Radiofrequency Ablation Catheter in the Ventricle: A Preclinical Model.

Circ Arrhythm Electrophysiol

January 2025

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN (T.H., M.E.R., O.Y., G.N.K., N.O., T.K., L.N., D.L.P., K.C.S.).

Background: Power-controlled radiofrequency ablation with irrigated-tip catheters has been the norm for ventricular ablation for almost 2 decades. New catheter technology has recently integrated more accurate tissue temperature sensing enabling temperature-controlled irrigated ablation. We aimed to investigate the in vivo ablation parameters and lesion formation characteristics in ventricular myocardium using a novel temperature-controlled radiofrequency catheter.

View Article and Find Full Text PDF

The introduction of devices for endovascular dialysis access creation (WavelinQ and Ellipsys) offers practitioners more options for access management in dialysis patients. Especially in terms of reducing the usage of central venous catheters, a native fistula is desirable as an initial dialysis access. We present a case in which a failed WavelinQ type fistula was reactivated using the Ellipsys procedure on the same arm.

View Article and Find Full Text PDF

Objective: To investigate the effectiveness of posterior lateral perforator flap in lower limb combined with free fibula for maxillary tissue defect repair.

Methods: Between December 2018 and December 2023, 16 patients with the maxillary malignant tumors were admitted. There were 10 males and 6 females, with an average age of 64.

View Article and Find Full Text PDF

Background: Breast reconstruction with the deep inferior epigastric perforator (DIEP) free flap has become the gold standard for autologous breast reconstruction. Flap take-back to the operating room (OR) is an uncommon but difficult situation, requiring prompt and accessible resources. We conducted a literature review and independent expert review to inform evidence-based perioperative algorithms in the event of DIEP flap compromise.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!