A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1036
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3154
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Exploiting thermochromic materials for the rapid quality assurance of physiotherapy ultrasound treatment heads. | LitMetric

Significant nonuniformities in the acoustic intensity distribution generated by physiotherapy ultrasound treatment heads are not uncommon, potentially leading to significant localised temperature rises and tissue damage. An acoustic absorber tile containing a thermochromic pigment has been developed to provide rapid quality assurance of physiotherapy ultrasound treatment heads by virtue of a thermochromic colour change, indicating the time-averaged intensity distributions generated by these devices. As a bench-top device, the use of the tile is designed to mimic the nature of the physiotherapeutic application, requiring minimal training. Two designs where thermochromic pigments are added to the various polymeric layers of the tile are presented. Testing has been conducted with two physiotherapy treatment heads of differing performance, one of them notably exhibiting a strong "hot-spot" in localised acoustic time-averaged intensity. Findings show good qualitative agreement with classical hydrophone scans. Techniques are explored for the correction of nonlinearities in the thermochromic relationship, to enhance the accuracy of quantitative assessment.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.ultrasmedbio.2012.01.021DOI Listing

Publication Analysis

Top Keywords

treatment heads
16
physiotherapy ultrasound
12
ultrasound treatment
12
rapid quality
8
quality assurance
8
assurance physiotherapy
8
time-averaged intensity
8
exploiting thermochromic
4
thermochromic materials
4
materials rapid
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!