In vitro solubility tests of hydroxyapatite, tetracalcium phosphate or tricalcium phosphate particles were performed in lactate, citrate, Gomoris or Michaelis buffer with pH 6.2 or 7.2 and in aqua destillata. The results showed that in general the solubility decreased in the order tetracalcium phosphate greater than tricalcium phosphate greater than hydroxyapatite, except for lactate or citrate buffer where the solubility order was tetracalcium phosphate = tricalcium phosphate greater than hydroxyapatite. The influence of the specific buffer used is much larger than either pH or specific calcium phosphate salt tested. The pH stability of lactate buffer and aqua destillata is very low, the other buffer solvents had a rather stable pH value.