In June 2006, the Radiation Studies Branch of the Centers for Disease Control and Prevention held a workshop to explore rapid methods of facilitating radiological triage of large numbers of potentially contaminated individuals following detonation of a radiological dispersal device. Two options were discussed. The first was the use of traditional gamma cameras in nuclear medicine departments operated as makeshift wholebody counters. Guidance on this approach is currently available from the CDC. This approach would be feasible if a manageable number of individuals were involved, transportation to the relevant hospitals was quickly provided, and the medical staff at each facility had been previously trained in this non-traditional use of their radiopharmaceutical imaging devices. If, however,substantially larger numbers of individuals (100’s to 1,000’s) needed radiological screening, other options must be given to first responders, first receivers, and health physicists providing medical management. In this study, the second option of the workshop was investigated--the use of commercially available portable survey meters (either NaI or GM based) for assessing potential ranges of effective dose (< 50, 50-250, 250-500,and >500 mSv). Two hybrid computational phantoms were used to model an adult male and an adult female subject internally contaminated with 241Am, 60Cs, 137Cs, 131I, or 192Ir following an acute inhalation or ingestion intake. As a function of time following the exposure, the net count rates corresponding to committed effective doses of 50, 250, and 500 mSv were estimated via Monte Carlo radiation transport simulation for each of four different detector types, positions, and screening distances.Measured net count rates can be compared to these values, and an assignment of one of four possible effective dose ranges could be made. The method implicitly assumes that all external contamination has been removed prior to screening and that the measurements be conducted in a low background, and possibly mobile, facility positioned at the triage location. Net count rate data are provided in both tabular and graphical format within a series of eight handbooks available at the CDC website (http://www.bt.cdc.gov/radiation/clinicians/evaluation).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3909989PMC
http://dx.doi.org/10.1097/hp.0b013e3182351660DOI Listing

Publication Analysis

Top Keywords

count rates
12
effective dose
12
net count
12
survey meters
8
radiological triage
8
rates corresponding
8
250 500
8
500 msv
8
guidance handheld
4
handheld survey
4

Similar Publications

Objective: To assess the research productivity, career advancement, grant funding, and scholarly impact of international medical graduates (IMGs) in academic cardiothoracic surgery.

Summary Background Data: Physician shortages undermine patient care and risk exacerbating inequities, especially in cardiothoracic surgery, which may lose a quarter of its workforce by 2050-the most substantial reduction in surgery. IMGs could help alleviate these shortages, but there is limited data about their academic experiences.

View Article and Find Full Text PDF

Intracytoplasmic sperm injection (ICSI) is a cornerstone in managing male infertility, especially in obstructive azoospermia (OA) and non-obstructive azoospermia (NOA), necessitating sperm retrieval via testicular sperm extraction (TESE) or microdissection TESE (mTESE). However, the varied post-sperm extraction processing methods pose uncertainty regarding optimal approaches. To address this, a systematic review following preferred reporting items for systematic review and meta-analysis protocols (PRISMA-P) guidelines was conducted, identifying 16 relevant studies.

View Article and Find Full Text PDF

A dynamic mass balance model was developed to simulate contamination dynamics in the process water of fresh and frozen fruits, vegetables and herbs (ffFVH) during processing and handling operations. The mass balance relates to the flux of water and product in a wash tank and the number of microbial cells released in the water, inactivated by the water disinfectant or transferred from the water back to the product. Critical variables describing microbial dynamics in water are: (i) the chemical oxygen demand (COD), as an indicator of the concentration of organic matter; (ii) free chlorine (FC) and particularly its antimicrobial fraction, hypochlorous acid (HOCl); and (iii) the microbial population levels.

View Article and Find Full Text PDF

Radial access is considered the preferred method for coronary angiography (CAG) and percutaneous coronary intervention. Radial artery thrombosis (RAT) stands out as the primary complication associated with trans-radial access. Our objective was to explore the occurrence of RAT and its associated risk factors.

View Article and Find Full Text PDF

Bone marrow metastasis of ovarian cancer: A two‑center retrospective study and literature review.

Mol Clin Oncol

March 2025

Department of Obstetrics and Gynecology, Faculty of Medicine, Oita University, Yufu, Oita 8795593, Japan.

Bone marrow metastasis (BMM) causes pancytopenia and disseminated intravascular coagulation (DIC), resulting in rapid mortality. The incidence of this disease is likely underestimated, with confirmed BMM occurring at approximately twice the rates expected clinically. The present study describes two detailed cases and includes a literature review of BMM caused by ovarian cancer.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!