A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison of 3-dimensional spinal reconstruction accuracy: biplanar radiographs with EOS versus computed tomography. | LitMetric

Study Design: Experimental study for systematic evaluation of 3-dimensional (3D) reconstructions from low-dose digital stereoradiography.

Objective: To assess the accuracy of EOS (EOS Imaging, Paris, France) 3-dimensional (3D) reconstructions compared with 3D computed tomography (CT) and the effect spine positioning within the EOS unit has on reconstruction accuracy.

Summary Of Background Data: Scoliosis is a 3D deformity, but 3D morphological analyses are still rare. A new low-dose radiation digital stereoradiography system (EOS) was previously evaluated for intra/interobserver variability, but data are limited for 3D reconstruction accuracy.

Methods: Three synthetic scoliotic phantoms (T1-pelvis) were scanned in upright position at 0°, ±5°, and ±10° of axial rotation within EOS and in supine position using CT. Three-dimensional EOS reconstructions were superimposed on corresponding 3D computed tomographic reconstructions. Shape, position, and orientation accuracy were assessed for each vertebra and the entire spine. Additional routine planer clinical deformity measurements were compared: Cobb angle, kyphosis, lordosis, and pelvic incidence.

Results: Mean EOS vertebral body shape accuracy was 1.1 ± 0.2 mm (maximum 4.7 mm), with 95% confidence interval of 1.7 mm. Different anatomical vertebral regions were modeled well with root-mean-square (RMS) values from 1.2 to 1.6 mm. Position and orientation accuracy of each vertebra were high: RMS offset was 1.2 mm (maximum 3.7 mm) and RMS axial rotation was 1.9° (maximum 5.8°). There was no significant difference in each of the analyzed parameters (P > 0.05) associated with varying the rotational position of the phantoms in EOS machine. Planer measurements accuracy was less than 1° mean difference for pelvic incidence, Cobb angle (mean 1.6°/maximum 3.9°), and sagittal kyphosis (mean less than 1°, maximum 4.9°).

Conclusion: The EOS image acquisition and reconstruction software provides accurate 3D spinal representations of scoliotic spinal deformities. The results of this study provide spinal deformity surgeons evidence pertaining to this new upright 3D imaging technology that may aid in the clinical diagnosis and decision making for patients with scoliosis.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BRS.0b013e3182518a15DOI Listing

Publication Analysis

Top Keywords

eos
10
computed tomography
8
3-dimensional reconstructions
8
axial rotation
8
position orientation
8
orientation accuracy
8
cobb angle
8
accuracy
6
position
5
comparison 3-dimensional
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!