A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Quantification of nanoparticles in aqueous food matrices using Particle-Induced X-ray Emission. | LitMetric

Quantification of nanoparticles in aqueous food matrices using Particle-Induced X-ray Emission.

Anal Bioanal Chem

Research Centre for the Physics of Matter and Radiation, Namur Research Institute for LIfe Sciences, University of Namur, Belgium.

Published: July 2012

Nanoparticles (NPs) of SiO(2) (15 nm) or Ag (20 - 40 nm) were dispersed in water, coffee and milk at several aqueous dilutions. The NPs dispersions concentrations were quantified with an ion beam technique: Particle-Induced X-ray Emission. Additional measurements in relation to the state of the NPs dispersions were done: particle size distribution by centrifuge liquid sedimentation and the extreme surface composition by X-ray photoelectron spectroscopy. The particle size distribution of SiO(2) and Ag NPs dispersions in water and Ag NPs in coffee remained mostly as primary particles with hydrodynamic diameters close to the reported pristine NPs diameter. SiO(2) NPs agglomerated in coffee. In milk, both NPs presented an adsorption with milk lipids. Extreme surface composition corroborated adsorption in milk and showed that SiO(2) agglomerates adsorb some coffee components. A linear tendency in the measurement of the concentration dilutions of all dispersions was measured, and a lack of media influence in the slope of each curve was found. Limits of detection with the current setup were estimated at 0.5 and 0.3 mg/ml for SiO(2) and Ag NPs, respectively.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00216-012-5895-9DOI Listing

Publication Analysis

Top Keywords

nps dispersions
12
sio2 nps
12
nps
9
particle-induced x-ray
8
x-ray emission
8
coffee milk
8
particle size
8
size distribution
8
extreme surface
8
surface composition
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!