Taking advantage of the specific characteristics of a transversely excited atmospheric (TEA) CO(2) laser, a sophisticated technique for the analysis of chromated copper arsenate (CCA) in wood samples has been developed. In this study, a CCA-treated wood sample with a dimension of 20 mm × 20 mm and a thickness of 2 mm was attached in contact to a nickel plate (20 mm × 20 mm × 0.15 mm), which functions as a subtarget. When the TEA CO(2) laser was successively irradiated onto the wood surface, a hole with a diameter of approximately 2.5 mm was produced inside the sample and the laser beam was directly impinged onto the metal subtarget. Strong and stable gas plasma with a very large diameter of approximately 10 mm was induced once the laser beam had directly struck the metal subtarget. This gas plasma then interacted with the fine particles of the sample inside the hole and finally the particles were effectively dissociated and excited in the gas plasma region. By using this technique, high precision and sensitive analysis of CCA-treated wood sample was realized. A linear calibration curve of Cr was successfully made using the CCA-treated wood sample. The detection limits of Cr, Cu, and As were estimated to be approximately 1, 2, and 15 mg/kg, respectively. In the case of standard LIBS using the Nd:YAG laser, the analytical intensities fluctuate and the detection limit was much lower at approximately one-tenth that of TEA CO(2) laser.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1364/AO.51.00B121 | DOI Listing |
J Gerontol A Biol Sci Med Sci
December 2024
GENUD Toledo Research Group, Faculty of Sport Sciences, University of Castilla-La Mancha, Toledo, Spain.
Mean middle cerebral artery velocity (MCAv) and the pulsatility index (PI), at rest and in response to exercise, are important markers of cerebrovascular health status in middle-aged adults, when vascular decline assumes substantial relevance. Thus, this study aimed to describe and compare the responses of MCAv and PI to incremental exercise. Two hundred and forty-eight volunteers (50-58 years, 55% women) completed a ramp test on a cycle-ergometer.
View Article and Find Full Text PDFFront Transplant
January 2025
Department of Surgical, Medical, Biomolecular Pathology and Intensive Care, University of Pisa, Pisa, Italy.
Background And Aims: There is growing interest in the environmental impact of surgical procedures, yet more information is needed specifically regarding liver transplantation. This study aims to quantify the total greenhouse gas emissions, or carbon footprint, associated with adult whole-size liver transplantation from donors after brain death, including the relevant back-table graft preparation.
Methods: The carbon footprint was calculated retrospectively using a bottom-up approach.
J Vet Emerg Crit Care (San Antonio)
January 2025
Department of Veterinary Surgical and Radiological Sciences, School of Veterinary Medicine, University of California, Davis, Davis, California, USA.
Background: Venous blood gas and acid-base analysis is often performed in cats and requires appropriate reference intervals (RIs) for interpretation. The currently available RIs were created from small numbers of cats, while current guidelines suggest that a minimum number of 40 samples is required for the creation of an accurate/appropriate RI.
Key Findings: In 41 healthy awake cats, pH, PCO, PO, sodium, potassium, ionized calcium, chloride, glucose, and plasma lactate concentrations were measured, while bicarbonate, standardized base excess, and anion gap were calculated.
Med Gas Res
June 2025
Zhejiang University School of Medicine, Hangzhou, Zhejiang Province, China.
High-concentration oxygen inhalation is the primary intervention to prevent perioperative hypoxemia. However, there are concerns that this may induce an imbalance in oxidation‒reduction processes, particularly in pediatric patients with compromised antioxidant defenses. This study aimed to evaluate the impact of varying intraoperative concentrations of oxygen inhalation on oxidative stress in children by analyzing plasma biomarkers, oxygenation indices, and the duration of surgery and oxygen inhalation.
View Article and Find Full Text PDFDrug Test Anal
January 2025
Department of Experimental and Clinical Toxicology, Institute of Experimental and Clinical Pharmacology and Toxicology, Center for Molecular Signaling (PZMS), Saarland University, Homburg, Germany.
Rapid and comprehensive qualitative and quantitative analytical procedures are crucial in 24/7 emergency toxicology (ET) to support diagnosis and treatment of acute intoxications and to monitor their progression and efficacy of detoxification strategies. This study aimed to develop the simultaneous qualitative and quantitative analysis of 62 drugs, as well as seven active metabolites in human blood plasma using an automated liquid chromatography (LC)-linear ion trap mass spectrometry (MS) screening system. Sample preparation was conducted by liquid-liquid extraction, and plasma concentrations were determined using an electronically stored 5-point calibration.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!