A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

The impact of prosthesis-patient mismatch on long-term survival after aortic valve replacement: a systematic review and meta-analysis of 34 observational studies comprising 27 186 patients with 133 141 patient-years. | LitMetric

Aims: Numerous studies have linked prosthesis-patient mismatch (PPM) after aortic valve replacement (AVR) to adverse outcomes. Its correlation with long-term survival has been described but with contradicting results. This systematic review and meta-analysis of observational studies aims to determine the hazard of PPM after AVR.

Methods And Results: The Medline and EMBase databases were searched for English-language original publications. Two researchers independently screened studies and extracted data. Pooled estimates were obtained by random effects model. Subgroup analyses were performed to detect sources of heterogeneity. The search yielded 348 potentially relevant studies; 34 were included comprising 27 186 patients and 133 141 patient-years. Defined by the universally accredited indexed effective orifice area <0.85 cm(2)/m(2), 44.2% of patients were categorized as having PPM. In 34.2 and 9.8% of patients moderate (0.65-0.85 cm(2)/m(2)) and severe (<0.65 cm(2)/m(2)) PPM was present, respectively. Prosthesis-patient mismatch was associated with a statistically significant increase in all-cause mortality (HR = 1.34, 95% CI: 1.18-1.51), but only a trend to an increase in cardiac-related mortality (HR = 1.51, 95% CI: 0.88-2.60) was recognized. Analysis by severity of PPM demonstrated that both moderate and severe PPM increased all-cause mortality (HR = 1.19, 95% CI: 1.07-1.33 and HR = 1.84, 95% CI: 1.38-2.45) and cardiac-related mortality (HR = 1.32, 95% CI: 1.02-1.71 and HR = 6.46, 95% CI: 2.79-14.97). Further analyses showed a consistent effect over separate time intervals during follow-up.

Conclusion: Prosthesis-patient mismatch is associated with an increase in all-cause and cardiac-related mortality over long-term follow-up. We recommend that current efforts to prevent PPM should receive more emphasis and a widespread acceptance to improve long-term survival after AVR.

Download full-text PDF

Source
http://dx.doi.org/10.1093/eurheartj/ehs003DOI Listing

Publication Analysis

Top Keywords

prosthesis-patient mismatch
8
long-term survival
8
aortic valve
8
valve replacement
8
systematic review
8
review meta-analysis
8
meta-analysis observational
8
observational studies
8
comprising 186
8
186 patients
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!