A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

[Correction of electrocardiogram signal baseline wander based on statistically weighted moving average filter]. | LitMetric

[Correction of electrocardiogram signal baseline wander based on statistically weighted moving average filter].

Sheng Wu Yi Xue Gong Cheng Xue Za Zhi

Department of Electronics Information Engineering, Guangzhou University, Guangzhou 510006, China.

Published: February 2012

Baseline wander (BW) is a common noise contaminating electrocardiogram (ECG). In order to effectively correct baseline of ECG signal and to preserve more latent components of ECG signal, this paper proposes a simple and novel filter based on statistically weighted moving average. Firstly, after the arrange between the maximum and the minimum of these sampling values in a moving window was divided into many sections with equal width, several segments [a(k), b(k)] including most samples were determined. Then, for every sample point in the moving window its weight was decided according to the criterion: its weight was set as 1 if the sampling value belongs to [a(k), b(k)], otherwise, as 0. Lastly, all these ECG sampling points with 1 weight were averaged to estimate the real baseline in the moving window. The algorithm was tested by simulated signal and real signal from www. physionet. org. The results showed that compared to traditional moving average filter and wavelet package (WP) translation, the proposed filter could more effectively correct baseline in ECG signal and result in less distortion to ECG signal.

Download full-text PDF

Source

Publication Analysis

Top Keywords

ecg signal
16
moving average
12
moving window
12
baseline wander
8
based statistically
8
statistically weighted
8
weighted moving
8
effectively correct
8
correct baseline
8
baseline ecg
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!