Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
BACKGROUND: Some properties of blood are modified post mortem. These modifications might give false-negative or false-positive results in infectious disease testing. Most CE-marked test equipment for infectious serology testing is not validated for testing post-mortal blood. Validation, however, is obligatory, if the results are used for the release of tissues for transplantation. MATHODS: Samples of pre- and post-mortem sera were obtained from 20 cornea donors, and the results were compared for anti-HIV-1/2, anti-HCV, HBsAg, and anti-HBc on the Siemens-BEP-III Automatic System. Negative post-mortem sera were spiked with standard sera (PEI anti-HCV IgG, PEI HBsAg ad 1000 standard, anti-HBc IgG (WHO) NIBSC 95/522, PEI anti-HIV-IV) in concentrations which give low- and high-positive results for the respective marker. RESULTS: All pre-mortem sera were negative for all markers. None of the post-mortem samples was false-positive. None of the spiked postmortem samples was false-negative. Technical errors occurred during the validation process but could be detected and eliminated. Serum samples should be centrifuged immediately after collection, and it must be taken into account that post-mortem serum could rarely lead to blockage of pipetting systems due to clotting phenomena. CONCLUSION: There is no indication that post-mortem samples give false-negative or false-positve results with the test system and test kits used. The procedure described might serve as a model for validating other test kits on post-mortem samples.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3267999 | PMC |
http://dx.doi.org/10.1159/000334481 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!