A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Low-energy broad-beam photon shielding data for constituents of concrete. | LitMetric

The ability of concrete to attenuate ionizing radiation intensity is assessed using its linear or mass attenuation coefficient. In this work, the broad-beam linear and mass attenuation coefficients of different types of soils and cements used for making concrete were measured at different photon energies (60-1333 keV), nearly spanning the diagnostic photon energy range, using a NaI detector. The mass attenuation coefficients of cement decreased from 0.133 ± 0.002 at 60 keV to 0.047 ± 0.003 at 1332.5 keV. For soils, the mass attenuation coefficient of those collected from the beach was the highest, decreasing from 0.176 ± 0.003 cm²/g at 60 keV to 0.054 ± 0.001 cm²/g at 1332.5 keV. Land soils had the least value, decreasing from 0.124 ± 0.002 cm²/g at 60 keV to 0.044 ± 0.003 cm²/g at 1332.5 keV. Limestone had smaller mass attenuation coefficients than the cement produced using it. The implication of the above is that for making concrete, beach sand should be preferred as the sand component of the concrete. Models of the form μ(L) = A(E) exp[B(E)ρ] and μ(m) = αln(E)+β are proposed for fitting the linear attenuation coefficient and mass attenuation coefficient data, respectively.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC5716411PMC
http://dx.doi.org/10.1120/jacmp.v13i2.3525DOI Listing

Publication Analysis

Top Keywords

mass attenuation
24
attenuation coefficient
16
attenuation coefficients
12
13325 kev
12
linear mass
8
making concrete
8
coefficients cement
8
0003 cm²/g
8
cm²/g kev
8
cm²/g 13325
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!