A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

An Electrochemical Sensor Based on Nanostructured Hollandite-type Manganese Oxide for Detection of Potassium Ions. | LitMetric

An Electrochemical Sensor Based on Nanostructured Hollandite-type Manganese Oxide for Detection of Potassium Ions.

Sensors (Basel)

Department of Physics, Chemistry and Biology, Faculty of Science and Technology, University of State of Sao Paulo (UNESP), Rua Roberto Simonsen 305, CEP 19060-900 Presidente Prudente - SP, Brazil; E-Mails: ;

Published: September 2012

The participation of cations in redox reactions of manganese oxides provides an opportunity for development of chemical sensors for non-electroactive ions. A sensor based on a nanostructured hollandite-type manganese oxide was investigated for voltammetric detection of potassium ions. The detection is based on the measurement of anodic current generated by oxidation of Mn(III) to Mn(IV) at the surface of the electrode and the subsequent extraction of the potassium ions into the hollandite structure. In this work, an amperometric procedure at an operating potential of 0.80 V (versus SCE) is exploited for amperometric monitoring. The current signals are linearly proportional to potassium ion concentration in the range 4.97 × 10(-5) to 9.05 × 10(-4) mol L(-1), with a correlation coefficient of 0.9997.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3290461PMC
http://dx.doi.org/10.3390/s90906613DOI Listing

Publication Analysis

Top Keywords

potassium ions
12
sensor based
8
based nanostructured
8
nanostructured hollandite-type
8
hollandite-type manganese
8
manganese oxide
8
detection potassium
8
electrochemical sensor
4
oxide detection
4
potassium
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!