We have investigated the pressure dependence of the detection sensitivity of CO(2), N(2)O and CH(4) using wavelength modulation spectroscopy (WMS) with distributed feed-back diode lasers in the near infrared region. The spectral line shapes and the background noise of the second harmonics (2f) detection of the WMS were analyzed theoretically. We determined the optimum pressure conditions in the detection of CO(2), N(2)O and CH(4), by taking into consideration the background noise in the WMS. At the optimum total pressure for the detection of CO(2), N(2)O and CH(4), the limits of detection in the present system were determined.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3292140PMC
http://dx.doi.org/10.3390/s100504686DOI Listing

Publication Analysis

Top Keywords

co2 n2o
12
n2o ch4
12
wavelength modulation
8
modulation spectroscopy
8
pressure dependence
8
dependence detection
8
detection sensitivity
8
background noise
8
detection co2
8
detection
7