A stress-induced myocardial perfusion abnormality (MPS), in the absence of angiographically significant epicardial coronary artery disease, is considered a "false-positive" test result. We hypothesized that echocardiography would provide complementary prognostic and pathophysiologic data relevant to the management of patients with MPS and normal coronary angiograms. Accordingly, left atrial volume index (LAVi) was assessed by echocardiography in 38 patients with false positive MPS as defined by normal coronary angiograms and 26 patients with true negative MPS from a total of 1,356 patients stressed from July 2006-May 2008. Pathologically abnormal elevation of LAVi (≥ 32 mL/m(2)) was observed in 16 of 19 women (84%) and 11 of 19 men (58%) in the false positive MPS (FPMPS) group while none of the patients in the true negative MPS (TNMPS) group had elevated LAVi. In the FPMPS group mean LAVi was significantly higher in women than men (40.64 ± 11.4 mL/m(2) versus 32.6 ± 10.5 mL/m(2), P = 0.01). The mean LAVi in the FPMPS group was significantly different from the TNMPS group (36.6 ± 11.6 versus 21 ± 7 mL/m(2), P = 0.000). A stepwise logistic regression determined BSA, LAV and LAVi as useful in predicting false positive and true negative MPS. All three were significant predictors (P < 0.01) and the area under the ROC curve was 0.91. Our findings in this relatively small cohort suggest that patients with false positive MPS have a greater increased LAVi.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1536/ihj.53.18 | DOI Listing |
Anal Chim Acta
February 2025
Food Inspection and Quarantine Technology Center of Shenzhen Customs, Shenzhen Academy of Inspection and Quarantine, Shenzhen, 518045, PR China.
Background: Ochratoxin A (OTA) is toxic secondary metabolites produced by fungi and can pose a serious threat to food safety and human health. Due to the high stability and toxicity, OTA contamination in agricultural products is of great concern. Therefore, the development of a highly sensitive and reliable OTA detection method is crucial to ensure food safety.
View Article and Find Full Text PDFBiosens Bioelectron
January 2025
Key Laboratory of Laboratory Medical Diagnostics, Ministry of Education, Department of Laboratory Medicine, Chongqing Medical University, Chongqing, China. Electronic address:
Isothermal amplification-based nucleic acid detection technologies have become rapid and efficient tools for molecular diagnostics. Sequence-specific monitoring methods are crucial for isothermal amplification, as they help identify the occurrence of extended primer dimers, which can lead to false positive results. Fluorescent aptamers are promising tools for real-time monitoring of isothermal amplification but are inherently limited by thermostability.
View Article and Find Full Text PDFSpectrochim Acta A Mol Biomol Spectrosc
January 2025
Clinical Research Institute, Department of Laboratory Medicine, The First Affiliated Hospital of Xiamen University, School of Medicine, College of Chemistry and Chemical Engineering, College of Energy, College of Physical Science and Technology, and Discipline of Intelligent Instrument and Equipment, Xiamen University, Xiamen 361005 China; Scientific Research Foundation of State Key Laboratory of Vaccines for Infectious Diseases, Xiang An Biomedicine Laboratory, Xiamen 361005 China. Electronic address:
As a zoonotic virus, highly sensitive detection of monkeypox virus is crucial for its prevention and control due to its rapid increase in cases worldwide and the extremely high risk of virus transmission. In this paper, based on the principle of antigen-antibody specific recognition, an ultrasensitive resonance Raman biosensing probe was prepared using a molecule with the bifunctionality of resonance Raman effect and capturing antibody; and with the strong affinity of the biotin-streptavidin (Bio-SA) system, Bio-antibody and SA test strips were prepared. To match the T-line of the test strip, a portable Raman instrument with a strip-shaped spot was designed.
View Article and Find Full Text PDFDiagn Microbiol Infect Dis
January 2025
CHRC, NOVA Medical School Faculdade de Ciências Médicas, NMS FCM, Universidade NOVA de Lisboa; Campo dos Mártires da Pátria 130, 1169-056 Lisboa, Portugal.
Despite its low incidence in Europe, rubella's immune status is still routinely assessed using commercial immunoassays. However, some discrepancies have been observed between these tests and the Immunoblot. The main objective of this study is to evaluate, by a commercial immunoblot, the immune status of a female population that had previously presented negative, low-positive, or equivocal rubella IgG with a commercial immunoassay.
View Article and Find Full Text PDFEur J Clin Microbiol Infect Dis
January 2025
Laboratory of Medical Microbiology, Ghent University Hospital, Ghent, Belgium.
Purpose: Mortality and morbidity of patients with bloodstream infection (BSI) remain high despite advances in diagnostic methods and efforts to speed up reporting. This study investigated the impact of reporting rapid Minimum Inhibitory Concentration (MIC)-results in Gram negative BSIs with the ASTar system (Q-linea, Uppsala, Sweden) on the adaptation of empirically started antimicrobial therapy. We performed a real-world study during which antimicrobial susceptibility testing (AST) results were instantly reported to the treating physician in an established multidisciplinary antimicrobial stewardship setting.