In this case report, we describe a cutaneous manifestation of extensive metallosis in a patient 4 months post-metal-on-metal total hip arthroplasty with a Pinnacle cup with dissociation of the liner from the shell and resultant stripe burnishing of the shell and notch wear of the femoral neck. Dissociation of a metal liner has not been previously reported with this implant. Cutaneous metallosis has only been reported once in the literature. Clinicians should heighten their suspicion for metallosis secondary to hardware failure when encountering patients with skin discoloration in the setting of a painful and poorly functioning hip arthroplasty. In patients with failure of a metal-on-metal prosthesis with a modular metal liner in the acetabular component, liner dissociation must be considered.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.arth.2012.01.008DOI Listing

Publication Analysis

Top Keywords

hip arthroplasty
12
cutaneous manifestation
8
total hip
8
liner dissociation
8
metal liner
8
liner
5
metallosis
4
manifestation metallosis
4
metallosis metal-on-metal
4
metal-on-metal total
4

Similar Publications

Purpose: To determine the patient demographics and incidence of hip arthroscopy after total hip arthroplasty using the PearlDiver database.

Methods: This is a retrospective study of patients undergoing total hip arthroplasty and arthroscopic hip surgery. The PearlDiver Claims Database was queried using Current Procedural Terminology (CPT) codes for records from 2010 to 2021.

View Article and Find Full Text PDF

Background: The pelvis is one of the most common areas for metastatic bone disease. We recently described the use of a minimally invasive percutaneous screw fixation of metastatic non-periacetabular pelvic lesions, with excellent results.

Description: The procedure can be completed in a standard operating theater without the need for special instruments.

View Article and Find Full Text PDF

Introduction: The outcomes of total hip arthroplasty (THA) are highly dependent upon the restoration of native hip biomechanics and optimal component positioning. Robotic technologies for THA have rapidly improved the accuracy of component positioning and maintaining the planned center of rotation. While robotic-assisted THA (RA-THA) has primarily been employed in surgically intricate cases, its potential benefits in scenarios of diminished surgical complexity remain less explored.

View Article and Find Full Text PDF

Bone marrow edema (BME), a notable manifestation during the progression of osteonecrosis of the femoral head (ONFH), exhibits significant associations with femoral head collapse, pain, and prognosis, howeverits' pathogenesis remains underexplored. In this study, specimens from patients undergoing total hip arthroplasty (THA) were analyzed. The results revealed significantly higher Visual Analog Scale (VAS) scores and CT low-density area ratio in the BME group compared to the control group.

View Article and Find Full Text PDF

A Unique Cause of Chronic Right Hip Pain and Unilateral Leg Swelling 10 Years Following Total Hip Arthroplasty.

Am J Phys Med Rehabil

November 2024

Department of Physical Medicine & Rehabilitation, University of Minnesota, Minneapolis, Minnesota.

Patient is a 64-year-old female with a history of right total hip arthroplasty (THA) who presented with progressive painful right lower extremity edema and chronic groin pain for 2 years. A CT scan from October 2021 revealed an expanding, large iliopsoas bursal fluid collection that caused compression of the right common femoral artery and vein in June 2023. Further workup excluded deep venous thrombosis or infectious causes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!