A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Clinical and radiographic evaluation of total hip arthroplasties using porous tantalum modular acetabular components: 5-year follow-up of clinical trial. | LitMetric

Objectives: Porous tantalum is a biomaterial newly applied for artificial joints. We present here 5-years follow-up report of a multicenter clinical trial of total hip arthroplasties (THA) with porous tantalum modular acetabular component (modular PTC).

Methods: Study participants received 82 hips in 79 cases, with 61.2 months follow-up on average. Age at operation was 60.9 years. Clinical results were evaluated using Merle d'Aubigne Postel score. Presence of implant loosening, periacetabular radiolucency, osteolysis, and gap filling were examined for radiographic results.

Results: Merle d'Aubigne Postel score improved from 10.0 to 16.4 points. All PTC were radiographically stable, with no evidence of progressive radiolucencies. Average polyethylene wear rate was 0.004 mm/year, with no periacetabular osteolysis. Fifteen hips (18.3%) showed a gap >1 mm; however, all showed bone filling within 12 months. PTC with oversized reaming was significantly less likely to have a gap. No implant failure was noted related to modularity. Resulting survival rate of modular PTC was 100% at 5 years.

Conclusions: Modular PTC showed excellent results at 5-years of follow-up. Some hips showed periacetabular gaps, which were filled with bone within 1 year. Further follow-up was needed to determine long-term efficacy.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s10165-012-0618-9DOI Listing

Publication Analysis

Top Keywords

porous tantalum
12
total hip
8
hip arthroplasties
8
tantalum modular
8
modular acetabular
8
clinical trial
8
5-years follow-up
8
merle d'aubigne
8
d'aubigne postel
8
postel score
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!