A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1034
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3152
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development and validation of a new clinically-meaningful rating scale for measuring lateral canthal line severity. | LitMetric

Background: Several scales have been employed for evaluating the effects of cosmetic treatments in the periorbital area. The Food and Drug Administration (FDA) has recently issued new recommendations specifying a rigorous process to validate new aesthetic scales.

Objectives: The authors describe and validate a new clinical rating scale: the Investigator's Global Assessment of Lateral Canthal Line (IGA-LCL) severity scale.

Methods: The new FDA recommendations were utilized to validate the new scale. The first step was concept elicitation (based on direct input from clinicians, patients, and literature) and evaluation of content validity (appropriateness of concepts). The resulting five-point scale provided detailed descriptions of the lateral canthal lines (LCL), including quantitative assessment of LCL length and depth. Performance parameters, including intra- and interrater reproducibility and construct validity, were then evaluated in clinical studies. Finally, the scale's threshold for clinically-meaningful benefit and the ability of the scale to detect change were confirmed in two Phase 2b clinical studies involving a total of 270 subjects.

Results: Content validity was established and the IGA-LCL scale showed excellent interrater reliability (weighted Kappa = 0.89) and interrater reliability (weighted Kappa = 0.77; Kendall's coefficient of concordance = 0.89). In clinical trials, the scale was sensitive enough to detect clinically-meaningful one- and two-point changes in LCL severity following treatment with topical botulinum toxin type A (BoNT-A). The authors observed statistically-significant correlations between the physician-rated IGA-LCL results and patient-reported outcomes.

Conclusions: The IGA-LCL scale was shown to be reliable, appropriate, and clinically meaningful for measuring LCL severity.

Download full-text PDF

Source
http://dx.doi.org/10.1177/1090820X12437784DOI Listing

Publication Analysis

Top Keywords

lateral canthal
12
scale
8
rating scale
8
content validity
8
clinical studies
8
iga-lcl scale
8
interrater reliability
8
reliability weighted
8
weighted kappa
8
lcl severity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!