Background: Inhaled dry powder mannitol has established in vivo therapeutic efficacy for enhancing mucociliary function. However, a single dose necessitates multiple inhalations of a sizeable powder mass. Nebulization of mannitol by vibrating mesh devices has recently been shown in vitro to impart similar dosing in a comparable or lesser treatment time. Nevertheless, the limited solubility of mannitol restricted fluid concentrations to 150 mg/mL. The present study examines the feasibility of higher solubility polyols that presumably possess similar therapeutic properties to mannitol but deliverable at higher concentrations to shorten treatment time. A secondary aim is to compare delivery by two commercially available mesh nebulizers-the Aeroneb® Go and PARI eFlow Rapid.
Methods: A series of formulations containing three polyols (mannitol, sorbitol, and xylitol) of increasing concentration in 1% w/v sodium chloride were nebulized. Aerosol characteristics and treatment times were determined primarily by laser diffraction.
Results: RESULTS indicate viscosity is the primary determinant of vibrating mesh nebulizer performance. For both nebulizers, xylitol 334 mg/mL exhibits the greatest osmolar output-double that of 150 mg/mL mannitol.
Conclusions: A nebulized xylitol solution has potential clinical application for promoting rapid mucociliary clearance. Both vibrating mesh nebulizers facilitate quick treatment times. Future in vivo studies would compare the efficacy of nebulized xylitol to commercial hyperosmolar agents and establish any potential polyol-associated antibacterial activity.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1089/jamp.2011.0961 | DOI Listing |
Drug Deliv Transl Res
January 2025
UCL School of Pharmacy, University College London, 29-39 Brunswick Square, London, WC1N 1AX, UK.
Small interfering RNA (siRNA) and messenger RNA (mRNA) have drawn considerable attention in recent years due to their ability to modulate the expression of specific disease-related proteins. However, it is difficult to find safe, robust, and effective RNA delivery systems suitable for pulmonary delivery to treat lung diseases. In this study, two cationic peptides, namely LAH4-L1 and PEGKL4, were employed as non-viral vectors for siRNA and mRNA delivery.
View Article and Find Full Text PDFJ Orthop Surg Res
January 2025
Center for Rehabilitation Research, School of Allied Health Sciences, Texas Tech University Health Sciences Center, Lubbock, TX, USA.
Background: The sacroiliac joints (SIJ) are specialized articulations in the pelvis that allow load transfer between the upper and lower body. Traumatic pelvic disruption often requires surgical fixation of at least one of these joints. Subsequent SIJ pain is associated with asymmetries in joint laxity or stiffness.
View Article and Find Full Text PDFDevice
December 2024
Department of Chemical and Biomolecular Engineering, University of Delaware, Newark, DE 19716.
Modeling aerosol dynamics in the airways is challenging, and most modern personalized tools consider only a single inhalation maneuver through less than 10% of the total lung volume. Here, we present an modeling pipeline to produce a device that preserves patient-specific upper airways while approximating deeper airways, capable of achieving total lung volumes over 7 liters. The modular system, called TIDAL, includes tunable inhalation and exhalation breathing capabilities with resting flow rates up to 30 liters per minute.
View Article and Find Full Text PDFAnaesth Crit Care Pain Med
December 2024
Perioperative Care Program, Perioperative Medicine Team, Telethon Kids Institute, Northern Entrance, Perth Children's Hospital, 15 Hospital Ave, Nedlands WA 6009, Perth, Australia; Division of Emergency Medicine, Anaesthesia and Pain Medicine, Medical School, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; School of Human Sciences, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; Institute for Paediatric Perioperative Excellence, The University of Western Australia, 35 Stirling Hwy, Crawley WA 6009, Perth, Australia; Department of Anaesthesia and Pain Medicine, Perth Children's Hospital, 15 Hospital Ave, Nedlands WA 6009, Perth, Australia. Electronic address:
Eur J Orthod
December 2024
Department of Prosthodontics and Orthodontics, Dental Institute, Faculty of Medicine, Jagiellonian University Medical College, Montelupich St. 4/108, 31-155 Krakow, Poland.
Background: The fear of pain during the various stages of orthodontic treatment with fixed appliances is a common concern of patients. Therefore, the present research aimed to thoroughly investigate the impact of bracket architecture on pain perception during active treatment, debonding, and adhesive removal.
Materials: One hundred consecutive patients who completed treatment with one of two bracket systems (2-slot brackets with an integral base or conventional twin brackets with foil mesh) were included in this prospective cohort study.
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!