Purpose: Displaced type 2 lateral end clavicle fractures have a tendency to delayed union or non-union. Various methods of stabilisation of the displaced lateral end fractures are described. The increasing use of implants to fix such fractures also necessitates extensive dissection for implant retrieval. Adequate reduction and minimal tissue trauma during implant placement and removal would be ideal modalities for fixation of such fractures.

Methods: All displaced type 2 lateral end clavicle fractures fulfilling our inclusion criteria were reduced with a small anterosuperior incision. Anteroposterior drill holes were made in both the fragments and a nonabsorabable polyester suture was passed through. The fracture was reduced and fixed with transacromial smooth Kirshner wires. The suture was tied with the knot superiorly in a figure-eight manner. The arm was supported in an arm pouch for six weeks. The Kirshner wire was routinely removed after six weeks in an out-patient department. Clinico-radiological outcome was studied at six weeks, and monthly intervals thereafter until union.

Results: All 16 fractures united. The mean average age of patients was 36.25 years with a SD of 11.35. There was no loss of reduction even after removal of Kirshner wires at six weeks. The mean average time of union was 10.75 weeks with a SD of 3.92. All patients regained near normal range of motion, and the mean average constant score at the end of one year was 98.37 with a SD of 2.87. All patients returned to preinjury level by the one-year follow-up. The range of motion remained the same in those who were followed up in successive years. Skin impingement with bent Kirshner wires were noted in four cases. Kirshner wires backed out in one case before six weeks but there was no loss of reduction. Infection and Kirshner wire breakage were not noted in our series.

Conclusion: The clinico-radiological outcomes with our modified tension band fixation for displaced type 2 lateral end clavicle fractures were encouraging and comparable with earlier studies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3385908PMC
http://dx.doi.org/10.1007/s00264-012-1514-9DOI Listing

Publication Analysis

Top Keywords

displaced type
16
type lateral
16
lateral clavicle
16
clavicle fractures
16
kirshner wires
16
modified tension
8
tension band
8
kirshner wire
8
loss reduction
8
range motion
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!