Introduction: An investigational 10% liquid intravenous immunoglobulin (IVIG) was studied in 63 patients with primary immunodeficiency (PID) at 15 study sites.
Methods: Patients were treated every 3 or 4 weeks with 254-1029 mg/kg/infusion of IVIG.
Results: Overall, Biotest-IVIG infusions were well tolerated. The proportion of infusions that were associated with adverse events during infusion, and up to 72 h after infusion, including those unrelated to study product, was 27.7% with an upper 95% confidence limit ≤30.6%. Two serious bacterial infections (SBIs) were observed resulting in a serious bacterial infection rate of 0.035 per person per year and an upper one-sided 99% confidence limit of ≤0.136 SBI/patient/year. The number of days of work or school missed due to infection were relatively low at 2.28 days/patient/year. Two patients were hospitalized for infection producing a rate of 0.21 hospitalization days/patient/year. The IgG half-life was approximately 30 days with variation among individuals.
Conclusions: Pharmacokinetic parameters of specific antibody activities were essentially the same as those of total IgG. Biotest-IVIG is safe and effective in the treatment of PID.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3389237 | PMC |
http://dx.doi.org/10.1007/s10875-012-9656-5 | DOI Listing |
Sci Rep
December 2024
Faculté des Sciences et Technologies, LEMTA - Université de Lorraine - CNRS UMR 7563, Boîte Postale 70239, Vandoeuvre les Nancy cedex, 54506, France.
The wetting characteristics of fluids play a crucial role in various fields of interface and surface science. Contact angle serves as a fundamental indicator of wetting behavior. However, accurate quantification of wetting phenomena even at the macroscale often poses challenges, particularly due to the hysteresis between receding and advancing contact angles.
View Article and Find Full Text PDFSci Rep
December 2024
Hubei Key Laboratory of Oil and Gas Drilling and Production Engineering, Yangtze University, Wuhan, 430100, China.
The application of classic foaming agent faces several issues, including excessive use of defoaming agent, inadequate defoaming, pipeline blockage due to silicone oil precipitation, and high development cost of the foaming agent. To address the aforementioned issues, a novel intelligent foaming agent was created. This resulted in the development of a new intelligent foaming and discharging agent system.
View Article and Find Full Text PDFSci Rep
December 2024
Department of Chemistry, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Magnetic supported ionic liquids are a unique subclass of ionic liquids that possess the ability to respond to external magnetic fields, combining the advantageous properties of traditional ILs with this magnetic responsiveness. A novel magnetic ionic nanocatalyst of FeO@SiO@CPTMS-DTPA was prepared by anchoring an ionic liquid, CPTMS-DTPA, onto the surface of silica-modified FeO. The morphology, chemical structure and magnetic property of the magnetic ionic nanocatalyst structure was characterized using scanning electron microscopy, X-ray powder diffraction, Fourier transformation infrared spectroscopy, vibrating sample magnetometer, and thermogravimetric analysis.
View Article and Find Full Text PDFBiomed Chromatogr
January 2025
Drug Metabolism and Pharmacokinetics, Laxai Life Sciences Pvt. Ltd, Hyderabad, India.
A highly sensitive and rapid LC-MS/MS method was developed and validated for the quantification of dexamethasone in rat plasma and brain tissue. Protein precipitation method was used for sample preparation. The separation of dexamethasone and the IS (labetalol) was achieved on an Atlantis dC column using an isocratic mobile phase (10 mM ammonium formate and acetonitrile, 25/75, v/v) delivered at 0.
View Article and Find Full Text PDFBiomed Chromatogr
January 2025
Beijing Harmony Health Medical Diagnostics Co., Ltd., Beijing, China.
In the context of personalized and precision medicine, simultaneous monitoring of different forms of vitamins A and E and their metabolites could help us better understand the status of vitamins A and E in the body. The aim of this study was to establish a method for simultaneous determination of 13 kinds of vitamins A and E and their metabolites in human serum. Serum samples were directly detected by LC-MS/MS after deproteinization.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!