Aims: Implantable cardioverter defibrillators (ICDs) are efficient in reducing mortality in patients with left ventricular systolic dysfunction. High-rate cut-off programming may be effective in reducing appropriate and inappropriate therapies, but as the long-term consequences on morbidity and mortality remain unclear, it is underutilized.

Methods And Results: We prospectively studied 365 consecutive patients (mean age 60 ± 10 years), with ischaemic (63%) or non-ischaemic cardiomyopathy and left ventricular dysfunction (mean ejection fraction 25 ± 7%), who were implanted with an ICD in primary prevention of sudden cardiac death (41% single chamber, 31% dual chamber, and 28% biventricular). All devices were programmed with a shock-only zone over 220 beats per minute (b.p.m.) and a monitoring zone between 170 and 220 b.p.m. During a median follow-up of 40 months, 41 patients received appropriate shocks (11.2%) and 24 inappropriate shocks (6.6%). Then, 306 patients never experienced any ICD shock (84%). Inappropriate discharges were related to supraventricular tachyarrhythmia in 10 patients, and noise/oversensing in 14 patients. Ventricular tachycardia episodes, sustained or not, were recorded in the monitoring zone in 43 patients (11.8%). Seven of these patients were symptomatic (1.9%), without lethal consequence. Sixty-two patients (17%) died: 35 from end-stage heart failure, 1 from unexplained sudden death, and 26 from a documented non-cardiac cause.

Conclusion: High-rate cut-off (220 b.p.m.) shock-only ICD programming, in primary prevention patients with reduced left ventricular ejection fraction, appeared to be safe during a long-term follow-up. It also resulted in a very low rate of discharges, which are known to be deleterious in this population.

Download full-text PDF

Source
http://dx.doi.org/10.1093/europace/eus028DOI Listing

Publication Analysis

Top Keywords

left ventricular
16
high-rate cut-off
12
primary prevention
12
patients
11
long-term follow-up
8
cut-off programming
8
implantable cardioverter
8
cardioverter defibrillators
8
prevention patients
8
patients left
8

Similar Publications

Sepsis-induced cardiomyopathy (SICM) is a life-threatening complication of sepsis characterized by myocardial dysfunction. SICM significantly increases mortality rates in sepsis. Despite its clinical relevance, SICM lacks a unified definition and standardized diagnostic criteria, complicating early identification and treatment.

View Article and Find Full Text PDF

The guide extension-facilitated ostial stenting (GEST) technique uses a guide extension catheter (GEC) to improve stent delivery during primary coronary angioplasty (PCI). GECs are used for stent delivery into the coronary arteries of patients with difficult anatomy due to tortuosity, calcification, or chronic total occlusion (CTO) vessels. Stent and balloon placement has become challenging in patients with increasing lesion complexity due to tortuosity, vessel morphology, length of the lesion, and respiratory movements.

View Article and Find Full Text PDF

Left ventricular assist devices (LVADs) have been used as a bridge to transplantation in patients with advanced heart failure. In this case, LVAD therapy was used as a destination therapy for 16 years, representing the longest documented and continuously ongoing support with the original implanted device.

View Article and Find Full Text PDF

The role of multimodality imaging in diabetic cardiomyopathy: a brief review.

Front Endocrinol (Lausanne)

December 2024

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, MN, United States.

Diabetic cardiomyopathy (DMCM), defined as left ventricular dysfunction in the setting of diabetes mellitus without hypertension, coronary artery disease or valvular heart disease, is a well-recognized entity whose prevalence is certainly predicted to increase alongside the rising incidence and prevalence of diabetes mellitus. The pathophysiology of DMCM stems from hyperglycemia and insulin resistance, resulting in oxidative stress, inflammation, cardiomyocyte death, and fibrosis. These perturbations lead to left ventricular hypertrophy with associated impaired relaxation early in the course of the disease, and eventually culminating in combined systolic and diastolic heart failure.

View Article and Find Full Text PDF

Background: Diagnosis of cardiac amyloidosis (CA) is often missed or delayed due to confusion with other causes of increased left ventricular wall thickness. Conventional transthoracic echocardiographic measurements like global longitudinal strain (GLS) has shown promise in distinguishing CA, but with limited specificity. We conducted a study to investigate the performance of a computer vision detection algorithm in across multiple international sites.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!