Background: The AdVance male sling (American Medical Systems, Minnetonka, MN, USA) has been shown to be an efficacious device in short-term studies for postprostatectomy incontinence (PPI), but long-term studies are lacking.

Objective: Examine the intermediate-term outcome with the AdVance sling for PPI management.

Design, Setting, And Participants: A multicentre prospective evaluation was conducted on consecutive patients treated for PPI in three European tertiary reference centres.

Intervention: Patients were implanted with the AdVance male sling with no associated surgery.

Outcome Measurements And Statistical Analysis: Measurements included daily pad usage, maximum flow rate (Qmax), postvoid residual urine (PVR), the International Consultation on Incontinence Questionnaire-Short Form, the Incontinence Quality of Life questionnaires, and complications of surgery. Paired Wilcoxon signed rank test univariable and multivariable analyses were used.

Results And Limitations: Follow-up was available for 156 patients for the majority of parameters. Pad usage was significantly decreased compared with baseline at 12 mo and 3 yr (p<0.0001). At 12 mo, 76.9% of patients could be classified as cured or improved; this percentage was maintained at 3 yr (76.8%). Cure rates (58.6% vs 42.3%) and improvement rates (23.2% vs 25.0%) were higher in patients with mild or moderate incontinence compared with severe incontinence. Univariable analysis showed that pretreatment pad usage and severity of incontinence were both significant predictors of success (p=0.0355 and p=0.0420, respectively). However, in multivariable analysis, only pad usage was an independent predictor of success. There were no perioperative or severe postoperative complications. Most complications were Dindo grade I. Seven patients required a second treatment for stress urinary incontinence. There was no worsening over time. Limitations of this study included no comparator group, quality of life questionnaires in only two centres, and no 24-h pad test.

Conclusions: The transobturator retroluminal repositioning sling suspension is effective and safe in the longer term for treating PPI.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.eururo.2012.02.038DOI Listing

Publication Analysis

Top Keywords

advance male
8
male sling
8
pad usage
8
treatment postprostatectomy
4
postprostatectomy male
4
male urinary
4
incontinence
4
urinary incontinence
4
incontinence transobturator
4
transobturator retroluminal
4

Similar Publications

Purpose: Precision medicine plays an important role in the treatment of patients with advanced melanoma. Despite its high incidence in White patients, advanced melanoma is rare in Asian countries, hampering prospective clinical trials targeting the Asian population. This retrospective study aimed to elucidate the real-world molecular diagnoses and outcomes of Japanese patients with melanoma using comprehensive genome profiling (CGP).

View Article and Find Full Text PDF

Conformational Antibodies to Proteolipid Protein-1 and Its Peripheral Isoform DM20 in Patients With CNS Autoimmune Demyelinating Disorders.

Neurol Neuroimmunol Neuroinflamm

March 2025

Neuroimmunology Laboratory and Neuroimmunology Research Section, IRCCS Mondino Foundation, Pavia, Italy.

Background And Objectives: Antibodies to proteolipid protein-1 (PLP1-IgG), a major central myelin protein also expressed in the peripheral nervous system (PNS) as the isoform DM20, have been previously identified mostly in patients with multiple sclerosis (MS), with unclear clinical implications. However, most studies relied on nonconformational immunoassays and included few patients with non-MS CNS autoimmune demyelinating disorders (ADDs). We aimed to investigate conformational PLP1-IgG in the whole ADD spectrum.

View Article and Find Full Text PDF

Objective: This study aimed to introduce and evaluate a novel software-based system, BioTrace, designed for real-time monitoring of thermal ablation tissue damage during image-guided radiofrequency ablation for hepatocellular carcinoma (HCC).

Methods: BioTrace utilizes a proprietary algorithm to analyze the temporo-spatial behavior of thermal gas bubble activity during ablation, as seen in conventional B-mode ultrasound imaging. Its predictive accuracy was assessed by comparing the ablation zones it predicted with those annotated by radiologists using contrast-enhanced computed tomography (CECT) 24 hours post-treatment, considered the gold standard.

View Article and Find Full Text PDF

Objective: Managing blood glucose levels is challenging for elite athletes with type 1 diabetes (T1D) as competition can cause unpredictable fluctuations. While fear of hypoglycemia during physical activity is well documented, research on hyperglycemia-related anxiety (HRA) is limited. HRA refers to the heightened fear that hyperglycemia-related symptoms will impair functioning.

View Article and Find Full Text PDF

Purpose: In this study, we investigated the performance of deep learning (DL) models to differentiate between normal and glaucomatous visual fields (VFs) and classify glaucoma from early to the advanced stage to observe if the DL model can stage glaucoma as Mills criteria using only the pattern deviation (PD) plots. The DL model results were compared with a machine learning (ML) classifier trained on conventional VF parameters.

Methods: A total of 265 PD plots and 265 numerical datasets of Humphrey 24-2 VF images were collected from 119 normal and 146 glaucomatous eyes to train the DL models to classify the images into four groups: normal, early glaucoma, moderate glaucoma, and advanced glaucoma.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!