Background: Ingestion of foreign bodies represents a common feature in psychiatric patients and prisoners. Bezoar is a conglomeration of partially or undigested foreign material in the gastrointestinal tract. These are classified into several types according to the materials which they are composed of, the least frequent being metals. There are few cases reported in the literature.

Clinical Case: We report a case of a patient with a pathological history of mental disorder. The patient complained of abdominal pain 24 h prior, and there were no other symptoms. Physical examination revealed pain in the upper quadrant without peritoneal irritation. Laboratory tests were normal and plain x-ray of the abdomen showed several metallic foreign bodies, some sharp, >5 cm in length and with intestinal prolongation. Surgical intervention was performed several hours later: gastrotomy to remove the gastric bezoar that was composed of several screws, nails, scrap metal, lighters, clothespins, radio antennas and one coin. Four metallic foreign bodies were found in the small bowel after reviewing the abdominal cavity, so enterotomy was also performed to remove them. Postoperative course was uneventful.

Conclusions: Surgical treatment must be considered in cases of multiple, large, sharp objects or complications. An exhaustive study of the case is essential to avoid delay in treatment and potential complications.

Download full-text PDF

Source

Publication Analysis

Top Keywords

metallic foreign
12
foreign bodies
12
foreign
5
[bezoar ingestion
4
ingestion metallic
4
foreign bodies]
4
bodies] background
4
background ingestion
4
ingestion foreign
4
bodies represents
4

Similar Publications

Metal mesh-assisted CT localization of soft tissue foreign bodies for minimally invasive dermatological surgery.

J Am Acad Dermatol

January 2025

Department of Plastic Surgery, The Second Hospital & Clinical Medical School, Lanzhou University, Lanzhou 730030, Gansu, China. Electronic address:

View Article and Find Full Text PDF

Contaminants are a major cause of seafood export rejections in foreign markets and have significantly impacted consumer health. This investigation addresses the issues of metal contamination and biochemical markers in Litopenaeus vannamei from East Midnapore, West Bengal, India. The analyzed metals included vanadium (V), chromium (Cr), manganese (Mn), cobalt (Co), nickel (Ni), copper (Cu), zinc (Zn), molybdenum (Mo), silver (Ag), gallium (Ga), germanium (Ge), arsenic (As), selenium (Se), strontium (Sr), tin (Sn), cadmium (Cd), mercury (Hg), and lead (Pb), using Inductively Coupled Plasma Mass Spectrometry (ICP-MS).

View Article and Find Full Text PDF

Dielectric Constant of a Single MoO Nanostructure.

Nano Lett

January 2025

Department of Physics, Memory and Catalyst Research Center, Hankuk University of Foreign Studies, Yongin, 17035, Republic of Korea.

MoO is a promising transition metal oxide due to its high dielectric constant (κ) and multifunctionality in electronic and optoelectronic applications. Oxidation-induced nanoscale MoO, synthesized via oxidation scanning probe lithography (o-SPL) of MoS, requires in-depth characterization of its dielectric properties. In this study, we measured the κ of a single MoO nanostructure, which was confirmed to be in the amorphous phase through water solubility tests and high-resolution transmission electron microscopy (HRTEM).

View Article and Find Full Text PDF

Intracardiac migration of inferior vena cava (IVC) filter or stent is a rare but potentially fatal complication of endovascular venous device placement. There is no consensus whether migrated stents should be surgically removed by open cardiac surgery or retrieved by the percutaneous endovascular route and whether an intervention should be performed immediately or expectantly. Herein, we report a 39-year-old female who received emergent left lobe living donor liver transplantation (LDLT) owing to posthepatectomy liver failure.

View Article and Find Full Text PDF

Trials were inconsistent while reporting findings on the benefits of the intermittent regimen. Recent conclusive evidence to show overall effect was limited. This review compared intermittent and daily iron folic acid supplementation (IFAS) on pregnancy outcomes.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!