A neutron diagnostic for high current deuterium beams is proposed for installation on the spectral shear interferometry for direct electric field reconstruction (SPIDER, Source for Production of Ion of Deuterium Extracted from RF plasma) test beam facility. The proposed detection system is called Close-contact Neutron Emission Surface Mapping (CNESM). The diagnostic aims at providing the map of the neutron emission on the beam dump surface by placing a detector in close contact, right behind the dump. CNESM uses gas electron multiplier detectors equipped with a cathode that also serves as neutron-proton converter foil. The cathode is made of a thin polythene film and an aluminium film; it is designed for detection of neutrons of energy >2.2 MeV with an incidence angle < 45°. CNESM was designed on the basis of simulations of the different steps from the deuteron beam interaction with the beam dump to the neutron detection in the nGEM. Neutron scattering was simulated with the MCNPX code. CNESM on SPIDER is a first step towards the application of this diagnostic technique to the MITICA beam test facility, where it will be used to resolve the horizontal profile of the beam intensity.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3673013DOI Listing

Publication Analysis

Top Keywords

neutron diagnostic
8
diagnostic high
8
high current
8
current deuterium
8
deuterium beams
8
neutron emission
8
beam dump
8
neutron
6
beam
6
beams neutron
4

Similar Publications

Background: To study the risk of cardiovascular disease (CVD) and other competing causes of death in older kidney cancer patients.

Methods: Data on older patients (aged 65 and above) diagnosed with kidney cancer between 1975 and 2018 were extracted from the Surveillance, Epidemiology, and End Results (SEER) database. We delved into the distribution of CVD and other competing causes of death across the entire cohort and in various patient subgroups.

View Article and Find Full Text PDF

Objective: This study aimed to evaluate the predictive performance of inflammatory and nutritional indices for adverse cardiovascular events (ACE) in patients with acute myocardial infarction (AMI) after percutaneous coronary intervention (PCI) using a machine learning (ML) algorithm.

Methods: AMI patients who underwent PCI were recruited and randomly divided into non/ACE groups. Inflammatory and nutritional indices were graded according to the laboratory examination reports.

View Article and Find Full Text PDF

Revisiting the neuroanatomy of Massetognathus pascuali (Eucynodontia: Cynognathia) from the early Late Triassic of South America using Neutron Tomography.

Naturwissenschaften

January 2025

Programa de Pós-Graduação em Biodiversidade Animal, Universidade Federal de Santa Maria, Av. Roraima 1000, 97105-900, Santa Maria, RS, Brazil.

This paper analyzes the paleoneurology (cranial endocast and maxillary canal) of Massetognathus pascuali, an iconic non-mammaliaform cynodont from the early Late Triassic of South America, using Neutron Tomography. The application of neutron tomography holds the potential for uncovering more refined anatomical and quantitative data. The newly examined cranial endocast shows a forebrain with a tubular shape without an interhemispheric fissure, presence of a pineal body (with a closed parietal foramen), and a marked unossified zone.

View Article and Find Full Text PDF

A wealth of details regarding an individual's state of health, like a person's respiratory and metabolic functioning, can be studied by analyzing the volatile molecules and atoms in human exhaled breath. Besides, the salinity of seawater is a crucial factor in understanding its characteristics because any variation in the salinity of seawater represents the variations in the hydrological, biological, and chemical distributions. In this paper, a symmetrical one-dimensional phononic structure is theoretically designed using two symmetrical crystals separated with a defective cavity.

View Article and Find Full Text PDF

This paper explores the adaptation and application of i-TED Compton imagers for real-time dosimetry in Boron Neutron Capture Therapy (BNCT). The i-TED array, previously utilized in nuclear astrophysics experiments at CERN, is being optimized for detecting and imaging 478 keV gamma-rays, critical for accurate BNCT dosimetry. Detailed Monte Carlo simulations were used to optimize the i-TED detector configuration and enhance its performance in the challenging radiation environment typical of BNCT.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!