The generation of fast highly charged metal ions with the use of the sub-nanosecond Prague Asterix Laser System, operated at a fundamental wavelength of 1315 nm, is reported. Particular attention is paid to shot-to-shot reproducibility in the ion emission. Au and Pd targets were exposed to intensities up to 5 × 10(16) W∕cm(2). Above the laser intensity threshold of ∼3 × 10(14) W∕cm(2) the plasma is generated in a form of irregular bursts. The maximum energy of protons constituting the leading edge of the fastest burst reaches a value up to 1 MeV. The fast ions in the following bursts have energy gradually decreasing with the increasing burst number, namely, from a value of about 0.5 MeV∕charge regardless of the atomic number and mass of the ionized species.

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3655528DOI Listing

Publication Analysis

Top Keywords

shot-to-shot reproducibility
8
fast highly
8
highly charged
8
charged metal
8
metal ions
8
reproducibility emission
4
emission fast
4
ions laser
4
laser ion
4
ion source
4

Similar Publications

We report an efficient sample preparation method (freezing) for onsite fat and meat analysis via a specially designed thermoelectric cooling and temperature-controlling system. This investigation also focused on the effect of phase change on the sensitivity and reproducibility of LIBS emission signals and plasma parameters. The plasma emissions of animal fats (lard) were recorded when the sample was frozen (-2 °C), fluid (15 °C), and in a liquid state (37 °C) with a thermoelectric cooling system.

View Article and Find Full Text PDF

Purpose: Abdominal imaging is frequently performed with breath holds or respiratory triggering to reduce the effects of respiratory motion. Diffusion weighted sequences provide a useful clinical contrast but have prolonged scan times due to low signal-to-noise ratio (SNR), and cannot be completed in a single breath hold. Echo-planar imaging (EPI) is the most commonly used trajectory for diffusion weighted imaging but it is susceptible to off-resonance artifacts.

View Article and Find Full Text PDF

Purpose: Diffusion-weighted (DW) imaging provides a useful clinical contrast, but is susceptible to motion-induced dephasing caused by the application of strong diffusion gradients. Phase navigators are commonly used to resolve shot-to-shot motion-induced phase in multishot reconstructions, but poor phase estimates result in signal dropout and Apparent Diffusion Coefficient (ADC) overestimation. These artifacts are prominent in the abdomen, a region prone to involuntary cardiac and respiratory motion.

View Article and Find Full Text PDF

Comparison of round and knife-edge-like cathodes on gas-puff implosions.

Phys Rev E

August 2023

Pontificia Universidad Catolica de Chile, Santiago 7820436, Chile.

Preionization is believed to play an important role on the implosion of gas-puff Z pinches. Some experiments have used an external preionization source, e.g.

View Article and Find Full Text PDF

High precision control of laser energy for laser-matter interaction studies.

Rev Sci Instrum

July 2023

Dynamic Compression Sector, Institute for Shock Physics, Washington State University, Argonne National Laboratory, Lemont, Illinois 60439, USA.

Precise, highly reproducible control of the laser energy is required for high confidence laser-matter interaction research such as in dynamic compression science and high energy density physics. The energy must be adjustable without affecting the pulse shape (time varying intensity) or beam smoothness. We have developed a convenient two-stage energy tuning method for a nominal 100 J, 351 nm (UV) laser.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!