Note: Ultrasonic liquid flow meter for small pipes.

Rev Sci Instrum

Robotics Institute, Beihang University, Beijing 100191, China.

Published: February 2012

An ultrasonic flow meter for small pipes is presented. For metal pipe diameter smaller than 10 mm, clamp-on ultrasonic contrapropagation flow meters may encounter difficulties if cross talk or the short acoustic path contributes to large uncertainty in transit time measurement. Axial inline flow meters can avoid these problems, but they may introduce other problems if the transducer port is not properly positioned. Three types of pipe connecting tees are compared using the computational fluid dynamics (CFD) method. CFD shows the 45° tee has more uniform velocity distribution over the measuring section. A prototype flow meter using the 45° tee was designed and tested. The zero flow experiment shows the flow meter has a maximum of 0.002 m∕s shift over 24 h. The flow meter is calibrated by only 1 meter factor. After calibration, inaccuracy lower than 0.1% of reading was achieved in the laboratory, for a measuring range from 15 to 150 g∕s (0.29 to 2.99 m∕s; Re = 2688 to 26,876).

Download full-text PDF

Source
http://dx.doi.org/10.1063/1.3687780DOI Listing

Publication Analysis

Top Keywords

flow meter
20
flow
8
meter small
8
small pipes
8
flow meters
8
45° tee
8
meter
6
note ultrasonic
4
ultrasonic liquid
4
liquid flow
4

Similar Publications

A New Approach to Non-Invasive Microcirculation Monitoring: Quantifying Capillary Refill Time Using Oximetric Pulse Waves.

Sensors (Basel)

January 2025

Beijing Tsinghua Changgung Hospital, School of Clinical Medicine, Tsinghua University, 168 Litang Road, Changping District, Beijing 102218, China.

(1) Background: To develop a novel capillary refill time measurement system and evaluate its reliability and reproducibility. (2) Methods: Firstly, the utilization of electromagnetic pressure technology facilitates the automatic compression and instantaneous release of the finger. Secondly, the employment of pressure sensing technology and photoelectric volumetric pulse wave analysis technology enables the dynamic monitoring of blood flow in distal tissues.

View Article and Find Full Text PDF

: Chronic obstructive pulmonary disease (COPD) is a frequent but underdiagnosed disease, primarily due to the lack of access to forced spirometry (FS) in primary care. Portable, easy-to-use expiratory flow meters like Piko-6 and COPD-6 that measure FEV, FEV, and FEV/FEV ratio provide an alternative. Given that Piko-6 and COPD-6 devices measure FEV but not FVC, the aim of the study is to determine the optimal cutoff value for the FEV/FEV ratio of each device to avoid false negatives when these devices are used for COPD screening in primary care (PC).

View Article and Find Full Text PDF

Conventional techniques for evaluating hydration status include the analysis of blood, urine, and body weight. Recently, advancements in dentistry have introduced capacitance sensor-based oral epithelial moisture meters as promising avenues for assessment. This study aimed to examine the correlation between oral mucosal moisture content, as determined using a capacitance sensor, and exercise-induced dehydration.

View Article and Find Full Text PDF

Freeway continuous merging areas in a short distance exist continuous multiple ramps. In these areas, traffic flow and vehicle interactions are more complex, and traffic crashes and congestion are more frequent, which has been a major concern influencing traffic operation of freeways. Active traffic management (ATM) measures can improve traffic efficiency and reduce traffic risks in merging areas.

View Article and Find Full Text PDF

Purpose: To report a successful case of vision restoration and macular reperfusion following branch retinal artery occlusion (BRAO) using pars plana vitrectomy with undermining the artery off the retinal bed.

Methods: This case report involves a 75-year-old patient who was diagnosed immediately with BRAO following cardiac catheterization procedure. An embolus at the superior retinal artery bifurcation was noted.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!