AI Article Synopsis

  • The study aimed to monitor brain blood flow and oxygen levels during total aortic arch replacement surgery using transcranial Doppler (TCD) and near-infrared spectroscopy (NIRS).
  • 12 adult patients underwent deep hypothermic circulatory arrest and antegrade selective cerebral perfusion, with TCD and NIRS monitoring hemodynamic parameters throughout the surgery.
  • All patients survived without neurological complications, showing significant correlations between blood flow velocity and cerebral oxygen levels, suggesting that TCD and NIRS are useful for protecting brain function during such procedures.

Article Abstract

The purpose of this investigation was to use combined transcranial cerebral Doppler (TCD) and near-infrared spectroscopy cerebral oxygen saturation (NIRS) during total aortic arch replacement (TAAR) to monitor middle cerebral artery blood flow velocity and regional cerebral oximetry (rSO(2)) changes to provide a clinical basis for protective measures that may decrease injury of the central nervous system. Consecutive 12 adult patients underwent deep hypothermic circulatory arrest (DHCA) and antegrade selective cerebral perfusion (ASCP) during TAAR. A TCD probe was placed at the temporal windows after induction of anesthesia and the NIRS probe placed on the forehead of patients to collect perioperative, intraoperative, and postoperative hemodynamic parameters, and cerebral blood flow (CBF) and rSO(2) during cardiopulmonary bypass (CPB). In this retrospective case series, all patients survived, and there were no postoperative neurologic complications. There was no significant correlation between the mean arterial pressure and rSO(2). The middle cerebral artery mean velocity (VmMCA) and rSO(2) were significantly correlated, and main pump flow significantly correlated with rSO(2). After ASCP, VmMCA, rSO(2), and venous oxygen saturation were significantly lower than before ASCP, but VmMCA and rSO(2) returned to pre-CPB levels postoperatively. After off pump, the flow of ASCP showed a significant positive correlation with VmMCA and rSO(2). During DHCA when ASCP flow was lower than 5 ml/kg/min, TCD could not detect the MCA blood flow signal. When the flow of ASCP was above keeping around 10 ml/kg/min, MCA CBF velocity was maintained and rSO(2) > 45%. The combination of TCD and NIRS can be effective in monitoring brain function during DHCA with ASCP and may provide a guide for decreasing brain injury during the TAAR procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1097/MAT.0b013e318241abd3DOI Listing

Publication Analysis

Top Keywords

vmmca rso2
16
oxygen saturation
12
blood flow
12
cerebral
9
rso2
9
transcranial cerebral
8
cerebral doppler
8
near-infrared spectroscopy
8
spectroscopy cerebral
8
cerebral oxygen
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!