Atrial fibrillation (AF) is the most common type of arrhythmia, and is characterized by a disordered contractile activity of the atria (top chambers of the heart). A popular treatment for AF is radiofrequency (RF) ablation. In about 2.4% of cardiac RF ablation procedures, the catheter is accidently pushed through the heart wall due to the application of excessive force. Despite the various capabilities of currently available technology, there has yet to be any data establishing how cardiac perforation can be reliably predicted. Thus, two new FBG based sensor prototypes were developed to monitor contact levels and predict perforation. Two live sheep were utilized during the study. It was observed during operation that peaks appeared in rhythm with the heart rate whenever firm contact was made between the sensor and the endocardial wall. The magnitude of these peaks varied with pressure applied by the operator. Lastly, transmural perforation of the left atrial wall was characterized by a visible loading phase and a rapid signal drop-off correlating to perforation. A possible pre-perforation signal was observed for the epoxy-based sensor in the form of a slight signal reversal (12-26% of loading phase magnitude) prior to perforation (occurring over 8 s).

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3279251PMC
http://dx.doi.org/10.3390/s120101002DOI Listing

Publication Analysis

Top Keywords

cardiac ablation
8
loading phase
8
perforation
6
fbg sensor
4
sensor contact
4
contact level
4
level monitoring
4
monitoring prediction
4
prediction perforation
4
perforation cardiac
4

Similar Publications

Which Brugada patient deserves continuous ECG monitoring through implantable loop recorder? An evidence update.

J Cardiovasc Med (Hagerstown)

February 2025

Division of Cardiology, Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, Rende (CS).

Brugada syndrome (BrS) is a genetic condition that increases the risk of life-threatening arrhythmias, which can result in sudden cardiac death (SCD). Implantable loop recorders (ILRs) have become a key tool in managing patients with unexplained syncope, and guidelines advise their use in individuals with recurrent, unexplained syncope or palpitations. However, the role of ILRs in inherited arrhythmic conditions like BrS remains a topic of debate.

View Article and Find Full Text PDF

Omnipolar mapping versus point-by-point mapping approach for catheter ablation of atrioventricular accessory pathway.

J Interv Card Electrophysiol

January 2025

Department of Cardiovascular Medicine, Dokkyo Medical University, 880 Kitakobayashi, Mibu, Shimotsugagun, Tochigi, 321-0293, Japan.

Background: The conventional mapping approach for the atrioventricular accessory pathway (AP) involves point-by-point mapping to identify the connection sites of the AP to the atria or ventricle and accurate interpretation of local electrograms. Omnipolar mapping technology (OMT) explains how vector and wave speed are produced by using both unipolar and bipolar signals to obtain omnipolar signals, directions, and conduction velocity. The aim of this study is to verify the effectiveness of OMT for catheter ablation of AP.

View Article and Find Full Text PDF

Radiofrequency ablation (RFA) is a safe and effective treatment for patients experiencing ventricular and atrial tachyarrhythmias. While complications after RFA are generally rare, the occurrence of coronary artery (CA) injury, albeit infrequent, can have significant clinical implications. Given the proximity of CAs to common ablation sites, understanding the interplay between RFA and CA perfusion pathophysiology is paramount.

View Article and Find Full Text PDF

We report a case of a patient with dilated cardiomyopathy who experienced recurrent ventricular tachycardia (VT) and multiple defibrillations following CRT-D implantation. Due to worsening cardiac function, the patient required surgical implantation of a left ventricular assist device (LVAD) as a bridge to heart transplantation. During the procedure, we used the Ensite three-dimensional mapping system to perform activation and substrate mapping of the VT targets, followed by endocardial and epicardial cryoballoon ablation of clinical VT.

View Article and Find Full Text PDF

Significance: Radiofrequency ablation to treat atrial fibrillation (AF) involves isolating the pulmonary vein from the left atria to prevent AF from occurring. However, creating ablation lesions within the pulmonary veins can cause adverse complications.

Aim: We propose automated classification algorithms to classify optical coherence tomography (OCT) volumes of human venoatrial junctions.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!