Background: Pseudohyperkalaemia is relatively uncommon in children, but needs to be considered in cases where extreme hyperkalaemia is associated with normal renal function.

Case: A previously well 12 year-old boy presented with new onset T cell acute lymphoblastic leukaemia associated with a high peripheral blood white cell count. Plasma biochemistry tests on a blood sample sent to the laboratory using a pneumatic tube system showed a high plasma potassium level of 16.6 mmol/l, with otherwise normal electrolytes and renal function. A 12-lead electrocardiogram was normal, with no changes suggestive of hyperkalaemia. Pseudohyperkalaemia was suspected, and further samples transported to the laboratory by foot showed normal plasma potassium levels. It was subsequently demonstrated that the pseudohyperkalemia was due to the lysis of leukaemic white cells during the transport of blood samples from the ward to the laboratory within the pneumatic tube system.

Conclusions: Paediatricians caring for children with haematological malignancies need to be aware of this cause of pseudohyperkalaemia so that unnecessary treatment, including the commencement of acute dialysis, is avoided. We recommend that blood samples collected from children with high white cell count malignancies are transported to the laboratory by foot rather than in pneumatic tube systems.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00467-012-2102-3DOI Listing

Publication Analysis

Top Keywords

pneumatic tube
16
blood samples
12
transport blood
8
white cell
8
cell count
8
laboratory pneumatic
8
plasma potassium
8
transported laboratory
8
laboratory foot
8
blood
5

Similar Publications

In hospitals, IV bags can be prepared in advance for logistical and microbial safety reasons in a compounding unit and then transported to wards. Transport of protein drugs using a pneumatic tube system has been reported to result in high particle levels. In this study, pneumatic tube transport of trastuzumab in saline polyolefin bags was compared to delivery by hospital porters using an electric platform truck in an underground tunnel system.

View Article and Find Full Text PDF

Quantitative sizing of microplastics up to 20 µm using ICP-TOFMS.

J Anal At Spectrom

January 2025

ETH Zurich, Department of Chemistry and Applied Biosciences Vladimir-Prelog-Weg 1 8093 Zurich Switzerland

A fundamental study of four different sample introduction systems was carried out to evaluate the upper size limit of microplastics measured by inductively coupled plasma-time-of-flight-mass spectrometry (ICP-TOFMS). Three different, certified microplastic samples (PS, PMMA and PVC) within a size range of 3-20 µm in suspension were measured. In this study, no particles larger than 10 µm could be detected using pneumatic nebulization for sample introduction.

View Article and Find Full Text PDF

Impact of pneumatic tube transportation on the aggregation of monoclonal antibodies in clinical practice.

Eur J Pharm Sci

January 2025

Laboratory of General Biochemistry and Physical Pharmacy, Ghent University, Ottergemsesteenweg 460, 9000 Ghent, Belgium; Biopharmaceutical Technology, TUM School of Life Sciences, Technical University of Munich, Emil-Erlenmeyer-Forum 5, 85354 Freising, Germany. Electronic address:

Postproduction handling and in-hospital transportation of antibody drugs cause mechanical stress, including interfacial and shear stress, that can induce antibody unfolding and aggregation. The handling practices differ significantly between hospitals and the impact on protein stability is unknown. For example, the mechanical stress caused by transport via pneumatic tube systems (PTS) on therapeutic antibody aggregation is a potential safety and quality gap.

View Article and Find Full Text PDF

Manual flagging failed to identify pseudohyperkalemia in acute myeloid leukemia: case report.

Int J Emerg Med

October 2024

Division of Nephrology, Department of Internal Medicine, UCSF Fresno Center for Medical Education and Research, 155 N Fresno St, Fresno, CA, 93701, USA.

Article Synopsis
  • Pseudohyperkalemia, often seen in chronic lymphocytic leukemia, is rare in acute myeloid leukemia (AML), but can pose diagnostic challenges, as shown in a case involving a 55-year-old man with severe leukocytosis and falsely elevated potassium levels.
  • Despite the lab's manual flagging system meant to identify such cases, it failed to function properly, leading to reliance on clinicians' instincts for the correct diagnosis of pseudohyperkalemia.
  • The incident was linked to pneumatic tube transport of blood samples, prompting the lab to consider enhancements in its flagging system and the importance of using whole blood for potassium measurements in cases of significant leukocytosis.
View Article and Find Full Text PDF
Article Synopsis
  • A 58-year-old woman experienced complications, including regurgitation and obstruction, after her SG and subsequent ring placement, necessitating a two-step endoscopic procedure with a new Luso-Cor esophageal stent for treatment.
  • After initial unsuccessful attempts to alleviate symptoms through dilatation, the stent was ultimately removed, revealing a partially eroded calibration ring, and the patient reported being asymptomatic afterward, leading to a conservative follow-up approach.
View Article and Find Full Text PDF