Treatment of estrogens and androgens in dairy wastewater by a constructed wetland system.

Water Res

The Institute of Agri-Food and Land Use, School of Biological Sciences, Queen's University Belfast, Belfast BT9 5AG, Northern Ireland, UK.

Published: May 2012

AI Article Synopsis

  • Constructed wetland systems (CWS) are effective and low-cost options for treating dairy farm wastewater, specifically in removing organic compounds and pathogens.
  • A year-long study found that CWS can significantly reduce estrogen levels, with an average removal efficiency of 95.2%, although occasional peaks in estrogen concentrations were not as effectively managed.
  • The system also demonstrated a mean removal efficiency of 92.1% for androgens, but further design improvements may be needed to better address high peaks of hormonal concentrations in the wastewater.

Article Abstract

Constructed wetland systems (CWS) have been used as a low cost bio-filtration system to treat farm wastewater. While studies have shown that CWS are efficient in removing organic compounds and pathogens, there is limited data on the presence of hormones in this type of treatment system. The objective of this study was to evaluate the ability of the CWS to reduce estrogenic and androgenic hormone concentration in dairy wastewater. This was achieved through a year long study on dairy wastewater samples obtained from a surface flow CWS. Analysis of hormonal levels was performed using a solid phase extraction (SPE) sample clean-up method, combined with reporter gene assays (RGAs) which incorporate relevant receptors capable of measuring total estrogenic or androgenic concentrations as low as 0.24 ng L(-1) and 6.9 ng L(-1) respectively. Monthly analysis showed a mean removal efficiency for estrogens of 95.2%, corresponding to an average residual concentration of 3.2 ng L(-1) 17β-estradiol equivalent (EEQ), below the proposed lowest observable effect concentration (LOEC) of 10 ng L(-1). However, for one month a peak EEQ concentration of 115 ng L(-1) was only reduced to 18.8 ng L(-1). The mean androgenic activity peaked at 360 ng L(-1) and a removal efficiency of 92.1% left an average residual concentration of 32.3 ng L(-1) testosterone equivalent (TEQ). The results obtained demonstrate that this type of CWS is an efficient system for the treatment of hormones in dairy wastewater. However, additional design improvements may be required to further enhance removal efficiency of peak hormone concentrations.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.watres.2012.01.056DOI Listing

Publication Analysis

Top Keywords

dairy wastewater
16
removal efficiency
12
constructed wetland
8
cws efficient
8
estrogenic androgenic
8
l-1
8
average residual
8
residual concentration
8
wastewater
5
cws
5

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!