Plasma von Willebrand factor (VWF), produced in and released from vascular endothelial cells by various stimuli including hypoxia, induces platelet aggregation under high shear stress and plays dual pivotal roles in haemostasis and thrombosis within arterioles, which are regulated by the size of vWF multimers (VWFMs). Patients with obstructive sleep apnoea (OSA) have increased risk of thrombotic cardiovascular events, but the pathogenesis is unclear. We examined the relationship between VWF and OSA by measuring VWF antigen (VWF:Ag), VWFMs, VWF collagen binding activity (VWF:CB) and a disintegrin-like, metalloproteinase, and thrombospiondin type 1 motifs 13. A total of 58 OSA patients were enrolled. Blood samples were collected before sleep, after sleep, and after one night of nasal continuous positive airway pressure therapy. Based on VWFM analysis, OSA patients were classified into three groups; consistently normal VWFMs (group 1, n=29), increased high molecular weight (HMW)-VWFMs at 06:00 h (group 2, n=18), and decreased or absent HMW-VWFMs at 06:00 h (group 3, n=11). Patients in group 3 had significantly worse apnoea/hypopnoea index; VWF:CB followed a similar pattern. We observed a significant decrease in platelet count between 21:00 h and 06:00 h in OSA patients, potentially associated with reduced larger VWFMs together with decreased VWF:Ag levels. Severe OSA may contribute to an arterial pro-thrombotic state.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1183/09031936.00186210 | DOI Listing |
Zh Nevrol Psikhiatr Im S S Korsakova
December 2024
Republican Scientific and Practical Center of Neurology and Neurosurgery, Minsk, Belarus.
Objective: To analyze the results of nocturnal breathing parameters during sleep based on nocturnal pulse oximetry and to study of characteristics of external respiration in genetically confirmed patients with dystrophic myotonia (DM).
Material And Methods: The subjects of the study were patients with genetically confirmed DM types 1 and 2 who were hospitalized in the neurological departments of the Republican Scientific and Practical Center for Neurology and Neurosurgery. The clinical picture of the disease, comorbidities, sleep questionnaires, laboratory tests, overnight pulse oximetry and spirometry were performed and analyzed.
Neuromodulation
December 2024
StimAire Corporation, Tucson, AZ, USA.
Introduction: Moderate-to-severe obstructive sleep apnea (OSA) affects a large segment of the US population and is characterized by repetitive and reversible obstruction of the upper airway during sleep. Untreated OSA is associated with increased incidence of heart attack, stroke, and motor vehicle accidents due to sleepiness. Continuous positive airway pressure is often prescribed, but most patients with OSA are nonadherent.
View Article and Find Full Text PDFJ Pers Med
December 2024
Department of Otorhinolaryngology-Head and Neck Surgery, Chuncheon Sacred Heart Hospital, Hallym University College of Medicine, Chuncheon 24252, Republic of Korea.
One prior study revealed that a newly developed auto-titrating mandibular advancement device (AMAD) could potentially enhance polysomnographic outcomes in individuals with obstructive sleep apnea (OSA). However, evidence regarding its impact on autonomic nervous system dysregulation in OSA remains limited. In this study, we aimed to compare the effects of conventional mandibular advancement devices (MADs) and AMDA on autonomic function.
View Article and Find Full Text PDFClocks Sleep
December 2024
UR2NF-Neuropsychology and Functional Neuroimaging Research Unit, at CRCN-Centre for Research in Cognition and Neurosciences and UNI-ULB Neuroscience Institute, Université Libre de Bruxelles (ULB), 1050 Brussels, Belgium.
Continued solicitation of cognitive resources eventually leads to cognitive fatigue (CF), i.e., a decrease in cognitive efficiency that develops during sustained cognitive demands in conditions of constrained processing time, independently of sleepiness.
View Article and Find Full Text PDFClocks Sleep
December 2024
Department of Electrical Engineering, Eindhoven University of Technology, 5612AP Eindhoven, The Netherlands.
Total sleep time (TST) misperception has been reported in obstructive sleep apnea (OSA). However, previous findings on predictors were inconsistent and predominantly relied on single-night polysomnography, which may alter patients' sleep perception. We leveraged advances in wearable sleep staging to investigate predictors of TST misperception in OSA over multiple nights in the home environment.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!