Velocity of mist droplets and suspending gas imaged separately.

J Magn Reson

New Mexico Resonance, 2301 Yale Blvd. SE, Suite C-1, Albuquerque, NM 87106-4352, USA.

Published: March 2012

Nuclear Magnetic Resonance Images (MRIs) of the velocity of water droplets and velocity of the suspending gas, hexafluoroethane, are presented for a vertical and horizontal mist pipe flow. In the vertical flow, the upward velocity of the droplets is clearly slower than the upward velocity of the gas. The average droplet size calculated from the average falling velocity in the upward flow is larger than the average droplet size of mist drawn from the top of the pipe measured with a multi-stage aerosol impactor. Vertical flow concentrates larger particles because they have a longer transit time through the pipe. In the horizontal flow there is a gravity-driven circulation with high-velocity mist in the lower portion of the pipe and low-velocity gas in the upper portion. MRI has the advantages that it can image both phases and that it is unperturbed by optical opacity. A drawback is that the droplet phase of mist is difficult to image because of low average spin density and because the signal from water coalesced on the pipe walls is high. To our knowledge these are the first NMR images of mist.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.jmr.2012.01.006DOI Listing

Publication Analysis

Top Keywords

suspending gas
8
vertical flow
8
upward velocity
8
average droplet
8
droplet size
8
velocity
6
mist
5
pipe
5
flow
5
velocity mist
4

Similar Publications

Unlabelled: Group A (GAS) is a major human pathogen that causes several invasive diseases including necrotizing fasciitis. The host coagulation cascade initiates fibrin clots to sequester bacteria to prevent dissemination into deeper tissues. GAS, especially skin-tropic bacterial strains, utilize specific virulence factors, plasminogen binding M-protein (PAM) and streptokinase (SK), to manipulate hemostasis and activate plasminogen to cause fibrinolysis and fibrin clot escape.

View Article and Find Full Text PDF

Control of Permanent Porosity in Type 3 Porous Liquids via Solvent Clustering.

ACS Appl Mater Interfaces

January 2025

Geochemistry Department, Sandia National Laboratories, Albuquerque, New Mexico 87123, United States.

Porous liquids (PLs) are an exciting new class of materials for carbon capture due to their high gas adsorption capacity and ease of industrial implementation. They are composed of sorbent particles suspended in a nonadsorbed solvent, forming a liquid with permanent porosity. While PLs have a vast number of potential compositions based on the number of solvents and sorbent materials available, most of the research has been focused on the selection of the sorbent rather than the solvent.

View Article and Find Full Text PDF

Suspended Slot Membrane Waveguide Based on Germanium-on-Silicon-on-Insulator at λ = 4.23 µm for CO Monitoring.

Micromachines (Basel)

November 2024

Institute of Microelectronics and Optoelectronics, Warsaw University of Technology, Koszykowa 75, 00-662 Warsaw, Poland.

In this work, we propose a novel suspended slot membrane waveguide (SSMW) utilizing a germanium-on-silicon-on-insulator (Ge-on-SOI) platform for carbon dioxide (CO) gas-sensing applications. The design and analysis focus on the absorption line of CO in the mid-infrared region, specifically at a wavelength of 4.23 µm.

View Article and Find Full Text PDF

Study of the pH effects on water-oil-illite interfaces by molecular dynamics.

Phys Chem Chem Phys

January 2025

Laboratorio de Espectroscopía Atómica y Molecular (LEAM), Universidad Industrial de Santander, Colombia.

Illite mineral is present in shale rocks, and its wettability behavior is significant for the oil and gas industry. In this work, the pH effects on the affinity between the (001) and (010) crystallographic planes of illite K(SiAl)(AlMg)O(OH) and direct and inverse emulsions were studied using molecular dynamics simulations. To develop the simulations, an atomistic model of illite was constructed following Löwenstein's rule.

View Article and Find Full Text PDF

Anastomotic leak occurrence is a severe complication after colorectal surgery. Considering the difficulty of treating these leaks and their impact on patient care, there is a strong need for an efficient prevention strategy. We evaluated a combination of extracellular vesicles (EVs) from rat adipose-derived stromal cells with a thermoresponsive gel, Pluronic® F127 (PF-127) to prevent anastomotic leaks.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!