Abnormal renal function is an independent risk factor for cardiac implantable electronic device (CIED) infection. The risk of CIED infection increases as the degree of renal dysfunction worsens with the highest risk observed in patients with stage V chronic kidney disease. A significant portion of these patients use a tunneled hemodialysis catheter (TDC) for dialysis therapy. These devices are associated with very high rates of catheter-related bacteremia (1.6-5.5 episodes of bacteremia per 1000 catheter days), and have been known to cause infection of CIED indwelling in the bloodstream. In this context, the cardiac device is exposed to the risk of infection due to the presence of renal failure and episodes of bacteremia related to TDCs. Both increase the risk of CIED infection. Once infected, a cardiac rhythm device carries a marked increase in morbidity and mortality. In this context, the combination of a TDC and a CIED indwelling in the bloodstream becomes a potentially deadly combination. Recent data have emphasized that epicardial CIED implantation reduces cardiac device infection in TDC patients. This report highlights the risk of CIED infection in renal patients, presents TDC's contribution to the cardiac device infection, and suggests recommendations to minimize the risk of CIED infection in chronic hemodialysis patients dialyzing with a TDC.

Download full-text PDF

Source
http://dx.doi.org/10.1111/j.1525-139X.2012.01053.xDOI Listing

Publication Analysis

Top Keywords

cied infection
20
risk cied
16
cardiac device
12
infection
9
cardiac implantable
8
implantable electronic
8
cied
8
episodes bacteremia
8
cied indwelling
8
indwelling bloodstream
8

Similar Publications

Temporary Transvenous Pacing Performed in the Intensive Care Unit or in the Catheterization Laboratory.

Pacing Clin Electrophysiol

January 2025

Service de rythmologie cardiaque, Hôpital Cardiologique Louis Pradel, Hospices Civils de Lyon, Lyon, France.

Background: Temporary transvenous pacing (TTP) is a common procedure, predominantly performed in the catheterization laboratory (cath lab) because of presumed lower complication rate. This study aims to evaluate the efficacy and safety of TTP placement in the ICU compared to TTP placement in the cath lab.

Methods: This retrospective, real-life study included all patients requiring TTP in a tertiary care ICU between 2019 and 2022.

View Article and Find Full Text PDF

Aims: Utilization of transvenous lead extraction/removal (TLE) for the management of cardiac implantable electronic device (CIED)-associated infective endocarditis (IE) remains low. The aim of this study was to examine the impact of hospital TLE procedural volume on TLE utilization and outcomes for patients with CIED-associated IE.

Methods And Results: Using the Nationwide Readmissions Database, we evaluated 21 545 admissions for patients (mean age 70 years, 39% female) with CIEDs hospitalized with IE at TLE centres.

View Article and Find Full Text PDF

The benefits of permanent cardiac pacing have been widely demonstrated. However, the literature on complications remains inconsistent. We lack precise information about the frequency of complications and their predictive factors in our center.

View Article and Find Full Text PDF

LVAD versus CIED Infections: Distinct Entities, Distinct Suppression Strategies.

Clin Infect Dis

December 2024

Division of Public Health, Infectious Diseases and Occupational Medicine, Department of Medicine, Mayo Clinic, Rochester, Minnesota, USA.

A distinction between infections of left ventricular assist devices (LVADs) and cardiac implantable electronic devices (CIEDs) is warranted as they differ markedly in incidence, microbiologic profiles, clinical presentations, and extraction feasibility. These differences necessitate tailored suppressive antibiotic therapy (SAT) strategies. This commentary highlights the need for device-specific SAT approaches.

View Article and Find Full Text PDF

Background: Cardiac implantable devices (CIED) such as pacemakers, implantable cardioverter-defibrillators, or cardiac resynchronization devices are implanted in selected patients with bradyarrhythmia and advanced heart failure. The invasive character of these procedures poses a risk of early complications such as pneumothorax, bleeding, infections, or dislocations.

Aims: There are no available data that analyzed the impact of the organization of procedures on the early complications risk after permanent pacing procedures.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!