Broken implants, especially broken wires at difficult sites, may pose a challenge for the treating orthopedic surgeon. We describe a method for extraction of a broken guidewire that was, protruding into the hip joint following the insertion of a proximal femoral nail. A 35-year-old man with displaced femoral neck fracture with ipsilateral fracture shaft of femur was operated and fixed with long proximal femoral nail. The guidewire of proximal screw broke during the process of drilling. The tip of the 2-cm-long broken guidewire was touching the articular surface. The guidewire was misdirected posteroinferiorly from its path for the insertion of the proximal screw (6.8 mm), this screw was removed and bone endoscopy was performed with a 30° arthroscope. The broken end of the guidewire was located under direct vision. The grasper was introduced with its jaws at the 8 O'clock position and its position was confirmed under a C-arm image intensifier in both anteroposterior and lateral views. The broken end of the guidewire was grasped and it was retrieved. The screw was replaced in its original track to complete the procedure. The fractures united and patient was asymptomatic when last followed-up at 12 months.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3270595PMC
http://dx.doi.org/10.4103/0019-5413.91646DOI Listing

Publication Analysis

Top Keywords

broken guidewire
20
guidewire protruding
8
protruding hip
8
hip joint
8
insertion proximal
8
proximal femoral
8
femoral nail
8
proximal screw
8
broken
7
guidewire
6

Similar Publications

Introduction: Delayed union, non-union, and unstable fixation can lead to fatigue fractures of orthopedic implants. Breakages typically occur at the fracture site or locking screw insertion, acting as stress concentration foci. This case report highlights a rare instance of a 3-part broken proximal femoral nail (PFN), extracted using a corticotomy-assisted method without knee joint violation.

View Article and Find Full Text PDF

Hardware breakage in the form of guide wire or drill bit is a devastating complication particularly if occurs around hip joint during cephalo-medullary nailing. It should be removed on urgent basis as it can migrate to the pelvic cavity and damages adjacent neuro-vascular bundle and visceral organ immediately as well joint arthritis later on. There are very few cases report available in the literature with retrieval techniques by using disc forceps, pituitary forceps, oversized reamers, arthrotomy with joint dislocation and through ilioinguinal approaches occasionally.

View Article and Find Full Text PDF

Objectives: The objective of this study was to evaluate adverse events and device events related to accessories used during ureteroscopy (URS).

Materials And Methods: Analysis was performed of the records available in the Manufacturer and User Facility Device Experience database in the United States. Information was collected on characteristics of problem, timing, manufacturer verdict, successful completion of planned surgery, prolonged anaesthesia and injury to patient or staff.

View Article and Find Full Text PDF

A 24-year-old male, with a body mass index (BMI) of 31.7 and a previous open reduction and internal fixation (ORIF) of the left ankle seven years ago, presented to the emergency department with a peri-implant, comminuted fibula fracture with broken hardware and syndesmotic injury. The nature of the revision surgery made proper guidewire placement during fibular nailing difficult.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!