A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function. | LitMetric

Aims: We evaluated the accuracy of three-dimensional speckle-tracking echocardiography (3DSTE) to evaluate left ventricular (LV) volumes, ejection fraction (EF), and global circumferential strain (CS) in comparison with cardiac magnetic resonance imaging (MRI) in a healthy population.

Methods And Results: A total of 45 out of 50 consecutive healthy subjects (38 males, age 45 ± 15 years) successfully underwent both 3DSTE and MRI on the same day. Three-dimensional echocardiography data sets were analysed using speckle tracking to measure LV end-diastolic and end-systolic volumes, EF, and global CS. With MRI, the method of discs approximation was used to obtain volumes and the EF, whereas CS was acquired using myocardial tissue tagging. Inter-technique comparisons included regression and the Bland-Altman analysis. For quantification of LV volumes, 3DSTE correlated well with MRI (r: 0.75-0.81), but volumes were significantly underestimated with relatively large biases (13-34 mL) and wide limits of agreement (SD: 11-25 mL). However, excellent accuracy was revealed for measurement of EF by 3DSTE with a good correlation (r: 0.91), minimal bias, and narrow limits of agreement (0.6 ± 1.7%) compared with MRI. For measurement of CS, a large mean bias was found between techniques (10.0%), despite narrow limits of agreement (SD: 1.7%) and a good correlation between techniques (r: 0.80).

Conclusion: Although 3DSTE-derived LV volumes are underestimated in most patients compared with MRI, measurement of the LVEF revealed excellent accuracy. Measurements of CS were systematically greater (i.e. more negative) with 3DSTE than MRI, which likely reflects various inter-technique differences that preclude direct comparability of their measurements.

Download full-text PDF

Source
http://dx.doi.org/10.1093/ehjci/jes030DOI Listing

Publication Analysis

Top Keywords

limits agreement
12
three-dimensional speckle-tracking
8
speckle-tracking echocardiography
8
cardiac magnetic
8
magnetic resonance
8
resonance imaging
8
left ventricular
8
ventricular volumes
8
3dste mri
8
volumes underestimated
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!