Download full-text PDF

Source
http://dx.doi.org/10.1093/ejcts/ezr034DOI Listing

Publication Analysis

Top Keywords

severe intraprosthetic
4
intraprosthetic regurgitation
4
regurgitation immobile
4
immobile leaflet
4
leaflet transcatheter
4
transcatheter aortic
4
aortic valve
4
valve implantation
4
severe
1
regurgitation
1

Similar Publications

Background: Transcatheter aortic valve implantation (TAVI) is a safe and effective therapy for patients with severe aortic stenosis. A Stuck leaflet and severe intraprosthetic regurgitation after valve implantation occur rarely but can lead to sudden haemodynamic deterioration. We encountered a case of a stuck leaflet following post-dilatation with the Edwards Sapien 3 Ultra RESILIA valve.

View Article and Find Full Text PDF

Total hip arthroplasty stands as a milestone in surgical success for alleviating hip arthritis-related pain and enhancing patients' quality of life. While complications persist, advancements like dual-mobility articulation aims to mitigate risks. This manuscript presents an unprecedented unique complication in a 60-year-old woman with a revision dual mobility THA.

View Article and Find Full Text PDF
Article Synopsis
  • The study aimed to assess the hemodynamic effects of commissural alignment (CA) in patients receiving self-expandable transcatheter aortic valves (TAVR) using two different devices: Evolut Pro (EP) and Acurate neo2 (AN2).
  • Analyzing 557 patients, the results showed that CA was linked to a significant reduction in the rate of commissural misalignment (CMA) compared to those without CA, leading to lower transvalvular gradients and less aortic regurgitation after one year.
  • Although patients with moderate/severe CMA experienced worsened aortic gradients and regurgitation rates, overall structural deterioration criteria were not met at
View Article and Find Full Text PDF

Severe intraprosthetic aortic insufficiency immediately after implantation of a SAPIEN 3 Ultra RESILIA valve with spontaneous resolution: case report.

Eur Heart J Case Rep

August 2024

Cardiovascular Medicine, Asia Medical Group, Sapporo Heart Center, Sapporo Cardio Vascular Clinic, North 49, East 16, 8-1, Higashi Ward, Sapporo 007-0849, Japan.

Background: Aortic insufficiency (AI) is often encountered in transcatheter aortic valve replacement (TAVR) but is only rarely haemodynamically significant. Even more uncommon is the occurrence of intraprosthetic AI that often leads to haemodynamic compromise requiring additional therapeutic intervention.

Case Summary: An 85-year-old female with severe aortic stenosis underwent elective TAVR with a size 23 mm SAPIEN 3 Ultra RESILIA (S3UR) valve.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!