A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery. | LitMetric

Flexible cardiac T1 mapping using a modified Look-Locker acquisition with saturation recovery.

Magn Reson Med

GE Healthcare, Global Applied Science Laboratory, Bethesda, Maryland, USA.

Published: March 2012

A modified Look-Locker acquisition using saturation recovery (MLLSR) for breath-held myocardial T(1) mapping is presented. Despite its reduced dynamic range, saturation recovery enables substantially higher imaging efficiency than conventional inversion recovery T(1) mapping because it does not require time for magnetization to relax to equilibrium. Therefore, MLLSR enables segmented readouts, shorter data acquisition windows, and shorter breath holds compared with inversion recovery. T(1) measurements in phantoms using MLLSR showed a high correlation with conventional single-point inversion recovery spin echo. In vivo T(1) measurements from normal and infarcted myocardium in 41 volunteers and patients were consistent with previously reported values. Twenty subjects were also scanned with MLLSR using an accelerated sampling scheme that required half the scan time (eight vs. 16 heartbeats) but yielded equivalent results. The flexibility afforded by the improved imaging efficiency of MLLSR allows the acquisition to be tailored to particular clinical needs and to individual patient's breath-holding abilities.

Download full-text PDF

Source
http://dx.doi.org/10.1002/mrm.24137DOI Listing

Publication Analysis

Top Keywords

saturation recovery
12
inversion recovery
12
modified look-locker
8
look-locker acquisition
8
acquisition saturation
8
imaging efficiency
8
recovery
6
mllsr
5
flexible cardiac
4
cardiac mapping
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!