A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Development of a new automated clean-up system for the simultaneous analysis of polychlorinated dibenzo-p-dioxins (PCDDs), dibenzofurans (PCDFs) and 'dioxin-like' polychlorinated biphenyls (dl-PCB) in flue gas emissions by GPC-SPE. | LitMetric

A comprehensive clean-up method for quantitative analysis of polychlorinated biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins and dibenzo-furans (PCDD/Fs) in one single extract of environmental samples was developed. Since the chemical nature and toxicity of planar PCBs are similar to those of PCDD/Fs, dioxin-like PCBs and PCDD/Fs are often surveyed together in their exposure assessments. The development of a method for the simultaneous analysis of PCBs and PCDD/Fs in environmental samples is invaluable. The automated clean-up system evaluated in this work consists of three additional steps after traditional extraction: the chromatography on gel permeation (GPC), the concentration of the solvent through the use of an in-line evaporation module and the further purification and separation of PCDDs/Fs and dl-PCBs on an alumina cartridge in the 'SPE module'. In this work, three fly ash samples from an interlaboratory study with different PCDD/F and PCB levels were Soxhlet-extracted and then cleaned up using an automated system. PCDD/Fs and PCBs were determined using isotope dilution and high resolution gas chromatography/high resolution mass spectrometry. The determined values of 17 PCDD/Fs were consistent with the certified values and the relative standard deviations (RSDs) of the determined values were less than 20%. The recoveries of (13)C labeled PCDD/Fs and planar PCBs, and their RSDs were within the ranges specified in EPA1613 and 1668a methods, respectively. An accurate and reliable method was successfully developed and can be used in the simultaneous analysis of PCDD/Fs and planar PCBs in environmental samples.

Download full-text PDF

Source
http://dx.doi.org/10.1039/c2em10881jDOI Listing

Publication Analysis

Top Keywords

simultaneous analysis
12
environmental samples
12
planar pcbs
12
pcbs pcdd/fs
12
automated clean-up
8
clean-up system
8
analysis polychlorinated
8
polychlorinated dibenzo-p-dioxins
8
polychlorinated biphenyls
8
pcdd/fs
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!