Focusing planar refractive mosaic lenses based on triangular prism microstructures have been used as an alternative approach for wide-bandpass monochromatization of high-energy X-rays. The strong energy dependence of the refractive index of the lens material leads to an analogous energy dependence of the focal length of the lens. The refractive mosaic lens, in comparison with the refractive lens of continuous parabolic profile, is characterized by a higher aperture because of reduced passive material. In combination with a well defined pinhole aperture in the focal plane, the transmittance of photons of an appropriate energy can be relatively high and photons of deviating energy can be efficiently suppressed. The photon energy can be tuned by translating the pinhole along the optical axis, and the bandwidth changed by selecting appropriate pinhole aperture and beam stop. This method of monochromatization was realised at the ANKA FLUO beamline using a mosaic lens together with a 20 µm pinhole and beam stop. An energy resolution of 2.0% at 16 keV has been achieved.

Download full-text PDF

Source
http://dx.doi.org/10.1107/S0909049511052307DOI Listing

Publication Analysis

Top Keywords

refractive mosaic
8
energy dependence
8
refractive lens
8
mosaic lens
8
pinhole aperture
8
energy
6
lens
5
desktop x-ray
4
x-ray monochromator
4
monochromator synchrotron
4

Similar Publications

Importance: Additional data are required regarding atropine treatment regimens for control of myopia progression.

Objective: To investigate the efficacy and safety of different atropine regimens for myopia in children.

Design, Setting, And Participants: This was a secondary analysis of the 3-year results of the 24-Month Myopia Outcome Study of Atropine in Children (MOSAIC) trial, called the MOSAIC2 trial.

View Article and Find Full Text PDF

Purpose: To investigate 2-year changes in macular choroidal thickness (ChT) in children receiving 0.01% atropine eyedrops and its relationship with spherical equivalent refraction (SER) progression and axial length (AL) elongation.

Methods: A total of 250 myopic children aged 6-16 years (167%-0.

View Article and Find Full Text PDF

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!