Functional outcomes in women after high-energy pelvic ring injury.

J Orthop Trauma

Department of Orthopaedic Surgery, MetroHealth Medical Center, Cleveland, OH 44109, USA.

Published: May 2012

Objectives: Residual dysfunction after pelvic trauma has been previously described, but limited functional outcome data are available in the female population after high-energy pelvic ring injury. The purposes of this study were to determine functional outcomes and to characterize factors predictive of outcome.

Design: Prospective collection of functional outcomes data.

Setting: Level I trauma center.

Patients/participants: Eighty-seven women with mean age of 33.5 years and mean Injury Severity Score of 23.1 were included. The Orthopaedic Trauma Association classification included 32 B-type and 55 C-type fractures. Four were open fractures and six had bladder ruptures.

Intervention: Forty-nine patients were treated operatively and 38 nonoperatively.

Main Outcome Measurements: Musculoskeletal Functional Assessment (MFA) questionnaires were completed after a minimum of 16 months and a mean of 41 months of follow-up.

Results: The mean MFA score was 33. Only 15 women (17.2%) had MFA scores comparable with an uninjured reference value (9.3), and 34 (39.1%) had better than the reference value for prior hip injury (25.5). Anteroposterior compression injuries had worse scores versus other patterns (48.3 vs 31.0, P = 0.01), and trends toward worse outcomes were noted after symphyseal disruption (P = 0.11) and transsymphyseal plating (P = 0.09). Sacral fracture or sacroiliac injury, amount of initial or final displacement, and type of posterior ring treatment were not associated with MFA scores. Mean scores were 32.3 after surgery and 34.0 after nonoperative management (P = 0.67). Functional outcomes were not related to age or Injury Severity Score, but isolated pelvis fractures had better MFA scores (21.1 vs 35.5, P = 0.008) and worse MFA scores (41.7 vs 29.1, P = 0.004) were seen with other lower extremity fractures. Those with bladder ruptures (n = 6) also had poor outcomes, mean MFA 50.0 (P = 0.078).

Conclusions: Wide variation is seen in functional outcome of women after high-energy pelvic ring fracture as measured by the MFA with mean scores demonstrating substantial residual dysfunction. Better outcomes were noted after isolated fractures and in women who had not sustained other fractures in their lower extremities. History of bladder rupture or anteroposterior compression injury was associated with poor MFA scores.

Level Of Evidence: Prognostic Level IV. See Instructions for Authors for a complete description of levels of evidence.

Download full-text PDF

Source
http://dx.doi.org/10.1097/BOT.0b013e318221e94eDOI Listing

Publication Analysis

Top Keywords

mfa scores
20
functional outcomes
16
high-energy pelvic
12
pelvic ring
12
mfa
9
women high-energy
8
ring injury
8
residual dysfunction
8
functional outcome
8
injury severity
8

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!