Severity: Warning
Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 176
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 316
Function: require_once
Study Objectives: To determine the effects of bilevel positive airway pressure with pressure release technology (Bi-Flex) on adherence and efficacy in children and adolescents compared to standard continuous positive airway pressure (CPAP) therapy. We hypothesized that Bi-Flex would result in improved adherence but similar efficacy to CPAP.
Methods: This was a randomized, double-blinded clinical trial. Patients with obstructive sleep apnea were randomized to CPAP or Bi-Flex. Repeat polysomnography was performed on pressure at 3 months. Objective adherence data were obtained at 1 and 3 months.
Results: 56 children and adolescents were evaluated. There were no significant differences in the number of nights the device was turned on, or the mean number of minutes used at pressure per night for CPAP vs Bi-Flex (24 ± 6 vs 22 ± 9 nights, and 201 ± 135 vs 185 ± 165 min, respectively, for Month 1). The apnea hypopnea index decreased significantly from 22 ± 21/h to 2 ± 3/h on CPAP (p = 0.005), and 18 ± 15/h to 2 ± 2/h on Bi-Flex (p < 0.0005), but there was no significant difference between groups (p = 0.82 for CPAP vs Bi-Flex). The Epworth Sleepiness Scale decreased from 8 ± 5 to 6 ± 3 on CPAP (p = 0.14), and 10 ± 6 to 5 ± 5 on Bi-Flex (p < 0.0005; p = 0.12 for CPAP vs Bi-Flex).
Conclusions: Both CPAP and Bi-Flex are efficacious in treating children and adolescents with OSAS. However, adherence is suboptimal with both methods. Further research is required to determine ways to improve adherence in the pediatric population.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3266335 | PMC |
http://dx.doi.org/10.5664/jcsm.1656 | DOI Listing |
Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!