A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

Experimental comparison of the measurement accuracy of the Licox(®) and Raumedic (®) Neurovent-PTO brain tissue oxygen monitors. | LitMetric

Background: Only a few experimental reports are available on the direct comparison of Licox(®) and Raumedic(®)-Neurovent-PTO brain tissue oxygen pressure (P(br)O(2)) monitors. We compared the two systems regarding their measurement properties under experimental in vitro and in vivo conditions.

Materials And Methods: Eight Licox(®) and Raumedic(®) Neurovent-PTO(®) sensors were tested for 10 min at 37°C, atmospheric pressure, at an oxygen content of 0% and 100% before and after the in vivo test. The same probes were implanted in German landrace pigs, which underwent hepatectomy. The mean P(br)O(2) values were recorded every minute. An O(2) challenge with inhalation of 100% O(2) for 10 min was performed 2 h post-abdominal surgery.

Results: At 0% O(2) content values varied from 0.2 to 7 mmHg, at 100% O(2) content from 130 to 165 mmHg. No difference between probes was found. In vivo tests: Raumedic® showed higher P(br)O(2) values (mean +6.3 mmHg, p < 0.0001) compared with Licox®. During O(2) challenge, both probes responded similarly; however, Raumedic(®) had a 10% higher response amplitude (p < 0.005). After explantation there was again no difference between the two sensors.

Conclusion: Raumedic(®) sensors measured higher P(br)O(2) values. There was no significant difference regarding overall measurement of in vitro accuracy between the two probes, which proved to be robust when used consecutively for longer periods and in different environments.

Download full-text PDF

Source
http://dx.doi.org/10.1007/978-3-7091-0956-4_32DOI Listing

Publication Analysis

Top Keywords

pbro2 values
12
brain tissue
8
tissue oxygen
8
higher pbro2
8
experimental comparison
4
comparison measurement
4
measurement accuracy
4
licox®
4
accuracy licox®
4
licox® raumedic
4

Similar Publications

Want AI Summaries of new PubMed Abstracts delivered to your In-box?

Enter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!