The paper describes a program of mechanical testing on donated human eye bank lenses. The principal purpose of the tests was to obtain experimental data on the shear modulus of the lens for use in future computational models of the accommodation process. Testing was conducted using a procedure in which deformations are induced in the lens by spinning it about its polar axis. Shear modulus data were inferred from these observed deformations by means of a finite element inverse analysis procedure in which the spatial variation of the shear modulus within the lens is represented by an appropriate function (see Burd et al., 2011 for a detailed specification of the design of the spinning lens test rig, experimental protocols and associated data analysis procedures that were employed in the tests). Inferred data on lens shear modulus are presented for a set of twenty-nine lenses in the age range 12 years to 58 years. The lenses were tested between 47 h and 110 h from the time of death (average post-mortem time 74 h). Care was taken to exclude any lenses that had been affected by excessive post-mortem swelling, or any lenses that had suffered mechanical damage during storage, transit or the testing process. The experimental data on shear modulus indicate that, for young lenses, the cortex is stiffer than the nucleus. The shear modulus of the nucleus and cortex both increase with increasing age. The shear modulus of the nucleus increases more rapidly than the cortex with the consequence that from an age of about 45 years onwards the nucleus is stiffer than the cortex. The principal shear modulus data presented in the paper were obtained by testing at a rotational speed of 1,000 rpm. Supplementary tests were conducted at rotational speeds of 700 rpm and 1,400 rpm. The results from these supplementary tests are in good agreement with the data obtained from the principal 1,000 rpm tests. Studies on the possible effects of lens drying during the test suggested that this factor is unlikely to have led to significant errors in the experimental determination of the shear modulus. The shear modulus data presented in the paper are used to develop 'age-stiffness' models to represent the shear modulus of the lens as a function of age. These models are in a form that may be readily incorporated in a finite element model of the accommodation process. A comparison is attempted between the shear modulus data presented in the current paper and equivalent data published by previous authors. This comparison highlights various limitations and inconsistencies in the data sets.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC3405528 | PMC |
http://dx.doi.org/10.1016/j.exer.2012.01.011 | DOI Listing |
J Mol Model
January 2025
Department of Mechanical Engineering, National Kaohsiung University of Science and Technology, Kaohsiung, 807, Taiwan.
Context: To address the severe fuel crisis and environmental pollution, the use of lightweight metal materials, such as AZ alloy, represents an optimal solution. This study investigates the mechanical behavior and deformation mechanism of AZ alloys under uniaxial compressive using molecular dynamics (MD) simulations. The influence of various compositions, grain sizes (GSs), and temperatures on the compressive stress, the ultimate compressive strength (UCS), compressive yield stress (CYS), Young's modulus (E), shear strain, phase transformation, dislocation distribution, and total deformation length is thoroughly examined.
View Article and Find Full Text PDFPhys Rev Lett
December 2024
CPT, CNRS, Aix Marseille Univ, Université de Toulon, (UMR 7332), Turing Center for Living Systems, Marseille, France.
Athermal (i.e., zero-temperature) underconstrained systems are typically floppy, but they can be rigidified by the application of external strain, which is theoretically well understood.
View Article and Find Full Text PDFIn Vitro Model
December 2024
Univ. Lille, Inserm, CHU Lille, Institut Pasteur Lille, U1167 - RID-AGE - Facteurs de Risque Et Déterminants Moléculaires Des Maladies Liées Au Vieillissement, F-59000 Lille, France.
Background: Extracellular matrix (ECM) is a three-dimensional (3D) structure found around cells in the tissues of many organisms. It is composed mainly of fibrous proteins, such as collagen and elastin, and adhesive glycoproteins, such as fibronectin and laminin-as well as proteoglycans, such as hyaluronic acid. The ECM performs several essential functions, including structural support of tissues, regulation of cell communication, adhesion, migration, and differentiation by providing biochemical and biomechanical cues to the cells.
View Article and Find Full Text PDFJ Ultrasound Med
January 2025
Department of Radiodiagnosis, Government Medical College and Hospital, Chandigarh, India.
Objectives: To determine the efficacy of quantitative shear wave elastography in differentiating benign and malignant axillary lymph nodes (ALN).
Methods: Exactly 127 lymph nodes from 127 patients with clinically palpable axillary swelling were examined by both B-mode sonography and elastography from November 2022 to March 2024. Gray-scale sonograms were evaluated based on: the short-axis diameter, shape, hilum, maximum cortical thickness, and border of the ALN.
J Appl Physiol (1985)
January 2025
Experimental Biomechanics Group, Institute of Structural Mechanics and Dynamics in Aerospace Engineering, Faculty of Aerospace Engineering and Geodesy, University of Stuttgart, Germany.
Characterizing individual muscle behavior is crucial for understanding joint function and adaptations to exercise, diseases, or aging. Shear wave elastography (SWE) is a promising tool for measuring the intrinsic material properties of muscle. This study assessed the passive and active shear modulus of the triceps surae muscle group in 14 volunteers (7 females, 25.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!