Aim: Nailfold capillaroscopy (NFC) is a simple, non-invasive method with exceptional predictive value for the analysis of microvascular abnormalities, especially in systemic sclerosis (SSc) but remains underutilized due to cost factors of the nailfold videocapillaroscope, lack of expertise and availability issues. The aim of this study was to establish the utility of an inexpensive digital microscope to study NFC changes in SSc in correlation with disease subsets and extent of skin involvement.
Methods: Twenty-two diffuse cutaneous SSc (DSS), 20 limited cutaneous SSc (LSS) patients and 42 controls were evaluated with NFC using a digital microscope at 30× and 100× magnification. Digital micrographs were used to study qualitative and quantitative changes in microvasculature.
Results: The capillary density was significantly less in all cases of SSc as compared to controls (5.3 ± 1.4 vs. 8.7 ± 1.2; P < 0.00001). Disorganized architecture was much more prevalent in DSS versus LSS (86.4%vs. 25%). The vascular deletion score (VDS) was significantly higher in DSS as compared to LSS (P < 0.0001). Scleroderma pattern (SP) was seen in 18 (81.9%) and 15 (75%) of patients with DSS and LSS, respectively. Only 4% of normal subjects showed non-specific pattern and none showed SP. The mean modified Rodnan skin score (MRSS) was positively correlated with vascular deletion score (r = 0.572; P < 0.001) and negatively with capillary density (r = -0.8; P < 0.001).
Conclusion: Nailfold capillaroscopy changes in SSc are related to disease subset and MRSS. NFC with digital microscope is a simplified, inexpensive, outpatient procedure with results comparable to previous studies.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1756-185X.2011.01699.x | DOI Listing |
Diagnostics (Basel)
March 2025
Department of Radiology, Radiation Oncology and Urology, Thomas Jefferson University, Philadelphia, PA 19107, USA.
The standard diagnostic approach for prostate cancer (PCa) diagnosis consists of serum prostate-specific antigen (PSA) testing, digital rectal examination (DRE) and image-guided targeted biopsies. Given the invasive nature, potential adverse events and costs associated with these techniques, alternative approaches have been investigated, specifically with serum and urine assays. The work presented here is intended to further validate a novel noninvasive optical technique for PCa detection, targeting the VPAC genomic receptors that are overexpressed on prostate cancer's malignant cells (MC), in non-DRE voided urine.
View Article and Find Full Text PDFSci Rep
March 2025
Mineral Resources Exploration Center of Henan Geological Bureau, Zhengzhou, 450002, China.
In response to friction and wear failure of the middle groove of a scraper conveyor, ultrasonic-assisted laser cladding technology was employed to prepare an Fe60/WC composite coating on the surface of 16Mn steel. The microstructure, hardness, friction and wear morphology, and other coating properties were tested and analysed using a microhardness tester, scanning electron microscope, ultradepth digital microscope, X-ray diffractometer (XRD), and friction and wear tester. This study examined the impact of ultrasonic-assisted laser cladding technology on the wear resistance of composite coatings.
View Article and Find Full Text PDFZhong Nan Da Xue Xue Bao Yi Xue Ban
October 2024
Xiangya Stomatological Hospital and Xiangya School of Stomatology, Central South University; Hunan Engineering Research Center for Digital Intelligence and Personalized Medicine; Hunan 3D Printing Engineering Research Center of Oral Care, Changsha 410008.
Objectives: Maxillary transverse deficiency is a common malocclusion frequently observed in orthodontic clinics. Miniscrew-assisted rapid palatal expansion (MARPE) not only produces greater skeletal expansion but also offers advantages such as simple miniscrew implantation without flap elevation, enhanced patient comfort, and an expanded age range and indications for palatal expansion. However, the fixed connection between the expander and the miniscrews makes the expander difficult to remove, significantly hindering its clinical application.
View Article and Find Full Text PDFFront Dent Med
February 2025
Research Center for Digital Technologies in Dentistry and CAD/CAM, Department of Dentistry, Faculty of Medicine and Dentistry, Danube Private University, Krems, Austria.
Objectives: The flexural strength and elastic modulus of rapidly prototyped denture base materials are affected by numerous factors including reinforcement with nanoparticles (NPs) and post-curing duration (PCD), though the effect of these two factors together has been overlooked. The present study tested the effect of nanodiamonds (NDs) or silicon dioxide nanoparticles (SNPs) with various PCDs on the flexural strength and elastic modulus of rapidly prototyped denture base materials.
Methods: To measure the flexural strength and elastic modulus, bar-shaped specimens (64 × 10 × 3.
Commun Eng
March 2025
Leibniz Institute of Photonic Technology, Albert-Einstein-Str. 9, 07745, Jena, Germany.
In biological imaging, there is a demand for cost-effective, high-resolution techniques to study dynamic intracellular processes. Structured illumination microscopy (SIM) is ideal for achieving high axial and lateral resolution in live samples due to its optical sectioning and low phototoxicity. However, conventional SIM systems remain expensive and complex.
View Article and Find Full Text PDFEnter search terms and have AI summaries delivered each week - change queries or unsubscribe any time!