The authors describe the case of a simultaneous mitral bioprosthesis hypertrophic scaring and native aortic valve fibrosis during benfluorex therapy in a 40-year-old woman. Four years before, she underwent a mitral valve replacement after the diagnosis of mitral regurgitation during benfluorex treatment (150 mg/day). This drug was reintroduced postoperatively. She presented with exercise and sometimes resting dyspnoea. The bioprosthesis and aortic valves exhibited similar histopathological lesions. Thickening and plaque deposits made by smooth muscle alpha actin- and vimentin-positive cells in a glycosaminoglycan matrix were observed. The study discusses the putative contribution of circulating progenitor cells activated by 5-HT(2B) receptor agonists in the development of drug-induced heart disease.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1111/j.1472-8206.2012.01027.x | DOI Listing |
Ann Thorac Surg Short Rep
September 2024
Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center and Children's Medical Center, Dallas, Texas.
Background: In small children with left atrioventricular valve dysfunction, valve repair is preferred but some will require valve replacement. No prosthetic valve has growth potential, bioprostheses have poor durability, and mechanical prostheses have high rates of thromboembolic and hemorrhagic complications. We reviewed our experience with a modified bovine jugular vein valve designed for use in the right ventricular outflow tract (Melody valve, Medtronic) and compared this with contemporary mechanical valve replacement.
View Article and Find Full Text PDFAnn Thorac Surg Short Rep
June 2024
University Department of Cardiac Surgery, Leipzig Heart Center, Leipzig, Germany.
Background: Comparative studies of outcomes between different biological mitral valve prostheses are scarce. This study compares the late clinical results of valve replacement with the Epic and Mosaic bioprostheses.
Methods: Patients undergoing isolated elective mitral valve replacement (MVR) between 2005 and 2019 were eligible for inclusion.
Eur Heart J Case Rep
December 2024
Paediatric Interventional Cardiology Unit, Vall d'Hebron Hospital, Paseo de la Vall d'Hebron, 119-129, 08035 Barcelona, Spain.
Background: The Edwards Sapien percutaneous valve (Edwards Lifesciences, Irvine, CA, USA) is a promising therapeutic option for congenital atrioventricular disease mostly because of the possibility to accommodate somatic growth with balloon dilatation.
Case Summary: This article reports the performance of the Edwards Sapien 3 valve in atrioventricular valve position in four paediatric patients.
Discussion: Despite aggressive antiplatelet and anticoagulation strategies, most patients showed early bioprosthesis dysfunction, with increasing gradient not related with somatic growth.
J Clin Med
November 2024
Department of Cardiac Surgery, Klinikum Nürnberg-Paracelsus Medical University, Breslauer Strasse 201, 90471 Nuremberg, Germany.
In recent years, the use of transcatheter valve-in-valve implantation in the mitral position (TMVI) for the treatment of mitral valve pathology following ring or bioprosthetic implantation has emerged as a less invasive option in comparison to repeated mitral valve surgery (RMVS). We aimed to compare the early and mid-term results of these two strategies. We retrospectively analyzed all patients who underwent a mitral intervention in our institution between 2005 and 2022.
View Article and Find Full Text PDFMed Eng Phys
December 2024
Department of Engineering, Università degli Studi di Palermo, Viale delle Scienze Ed.8, Palermo, Italy; Department of Research, IRCCS ISMETT via Tricomi, 5, Palermo, Italy. Electronic address:
Mixed reality (MR) has the potential to complement numerical simulations for enhanced post-processing and integrate digital models into the daily clinical practice of healthcare professionals. In complex cardiac anatomies, the decision-making process for bioprosthesis implantation involves the challenging analysis of heart valve distribution, positioning, and sealing. This study proposes a framework to visualize computational modeling results in an immersive environment for comprehensive analysis of the geometric implications of implanted devices on human heart function.