Tumor localization in patients has been achieved through the in vivo use of streptavidin and biotin. In these preliminary studies, the monoclonal antibody HMFG1 was conjugated with streptavidin and 1 mg was administered intravenously to each of 10 patients with documented squamous cell carcinoma of the lung. Two to 3 days later, 111In-labeled biotin was also administered intravenously. No evidence of toxicity was observed. Background radioactivity levels were reduced in liver (1% ID at 24 hr) and kidneys (2%) and in all other normal tissues and blood. Images of lung tumor were obtained in as little as 2 hr following administration of labeled biotin. In eight patients, tumor was detected with labeled biotin alone without the previous administration of streptavidin-conjugated antibody but in three of these patients, the images were improved with the prior administration of conjugated antibody. These results suggest that this approach may improve the tumor-to-normal tissue radioactivity ratios in radioimmunotargeting.