A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@pubfacts.com&api_key=b8daa3ad693db53b1410957c26c9a51b4908&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 176

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 176
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 250
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3122
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 575
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 489
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 316
Function: require_once

High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry. | LitMetric

High accuracy analysis of glucose in human serum by isotope dilution liquid chromatography-tandem mass spectrometry.

Clin Chim Acta

Chemical Metrology Laboratory, Applied Sciences Group, Health Sciences Authority, Singapore.

Published: April 2012

Background: An isotope dilution mass spectrometry (IDMS) technique has been developed for high accuracy analysis of glucose in human serum. Currently, all the IDMS methods for glucose analysis are based on gas chromatography-mass spectrometry (GC-MS). In this study, isotope dilution liquid chromatography-tandem mass spectrometry (ID LC-MS/MS) was investigated.

Methods: NIST SRM 965b glucose in frozen human serum was analyzed by linear regression IDMS based on both LC-MS/MS and GC-MS. Serum samples were spiked with isotope labeled glucose and deproteinized by acetonitrile. For LC-MS/MS measurement, the supernate was injected directly after filtration and dilution. For GC-MS measurement, the supernate was evaporated to dryness and went through a two-step derivatization before injection.

Results: All measurements had good precision with CVs of <1%. Results from GC-MS agreed very well with results from LC-MS/MS, with a difference of <0.7%. The final reporting values in this study, based solely on LC-MS/MS, were within the certified ranges. The relative expanded uncertainties were within the range of 1.37% to 1.69% for the 4 levels of glucose, which were comparable with uncertainties from the certificate.

Conclusions: The IDMS method based on LC-MS/MS is precise and accurate. It does not require lengthy derivatization steps and thus, greatly simplifies the sample preparation procedure.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.cca.2012.01.025DOI Listing

Publication Analysis

Top Keywords

human serum
12
isotope dilution
12
mass spectrometry
12
high accuracy
8
accuracy analysis
8
analysis glucose
8
glucose human
8
dilution liquid
8
liquid chromatography-tandem
8
chromatography-tandem mass
8